background image

FOR yOuR SAFETy

3

ADICOS M-BUSMASTER XF

420-2410-003 EN20

2  For your safety

WARNING!

Incorrect installation or operation can lead to death, serious injury and damage 

to industrial equipment.

•  Read this manual thoroughly and follow all of the instructions!

When properly installed, started up, operated and serviced, the 

ADICOS M-BUSMASTER XF

 

ensure  operational  safety  at  your  facility.  But  it  is  imperative  that  the  manual,  including  all 

safety notes, be read, understood and followed completely.

2.5  Intended Use

The 

ADICOS M-BUSMASTER XF

 is designed in line with state-of-the-art technology and ac

-

cepted safety regulations.

The device may be used only in compliance with the limits stated as technical operating spec

-

ifications. These can be found in 

Chap. 10, »Technical Data«

.

Intended use also includes following the instructions in this manual and complying with all 

relevant local regulations.

The 

ADICOS M-BUSMASTER XF

 may not be used for any other purpose. If the device is used 

in any other way, or if changes are made to the product, including in the course of installation 

and maintenance, the warranty claim is no longer valid.

2.6  Unintended Use

The 

ADICOS M-BUSMASTER XF

 may not be installed in potentially explosive areas.

2.7  Standards and Regulations

The safety and accident prevention regulations relevant to the specific application must be 

complied with when installing, starting up, servicing and inspecting the device.

The following standards and guidelines are particularly relevant:

Summary of Contents for M-BUSMASTER XF

Page 1: ...EN GTE Industrieelektronik GmbH Helmholtzstr 21 38 40 41747 Viersen Germany 49 2162 3703 0 info gte de XF Operating Manual M BUSMASTER...

Page 2: ...ltzstr 21 38 40 41747 Viersen GERMANY Support hotline 49 2162 3703 0 E Mail support adicos gte de 2020 GTE Industrieelektronik GmbH This document and all figures contained may not be copied changed or...

Page 3: ...heavy industry It controls communica tion with up to 255 ADICOS detectors via the ADICOS M Bus and serves as the interface be tween the ADICOS special fire detector and a service PC based standardly...

Page 4: ...Parts 4 3 Description of Product 5 3 1 Overview 6 3 2 Scope of Delivery 6 3 3 Terminal Assignment and Connections 7 3 4 Internal LED Indicators 9 3 5 Jumper 10 3 6 Fuses 11 4 Functioning 12 5 Install...

Page 5: ...III ADICOS M BUSMASTER XF 420 2410 003 EN20 9 Failure 21 10 Technical Data 22 10 1 Dimensions 23 11 Disposal 23 TABLE OF CONTENTS...

Page 6: ...d understand The following designations are used throughout Operational Objectives Operational objectives specify the result to be achieved by following the subsequent instruc tions Operational object...

Page 7: ...rous sit uation which could lead to minor injuries if it is not avoided NOTICE This combination of symbol and signal word indicates a possibly dangerous sit uation which could lead to property damage...

Page 8: ...y in compliance with the limits stated as technical operating spec ifications These can be found in Chap 10 Technical Data Intended use also includes following the instructions in this manual and comp...

Page 9: ...stallation of the ADICOS M BUSMASTER XF can cause malfunctioning leading to failure of the fire detection system Only properly trained personnel may perform installation work Only properly trained and...

Page 10: ...ates of all of the detectors in the system can be intelligently monitored with a service PC and the ADICOS central software All of the sensor data from the ADICOS fire detectors such as concentration...

Page 11: ...y voltage Connecting terminal ADICOS M Bus Connecting terminal service PC pre configured cables Cable duct Slot for Ethernet card optional 3 2 Scope of Delivery Check that the delivery is complete and...

Page 12: ...er feed 24 27 VDC check proper polarity Refer to circuit board label Current consumption max 4 A X2 M Bus output on ADICOS M BUSMASTER XF Connection for two wire bus system for communication with the...

Page 13: ...VAC L1 X1 2 Power supply 230 VAC N X2 1 M Bus output M Bus A X2 2 M Bus output M Bus B X2 3 Power supply 24 VDC GND 24 VDC X2 4 Power supply 24 VDC 24 VDC X3 1 RS 232 PC connection GND X3 2 RS 232 PC...

Page 14: ...eceived from the RS 232 interface or the higher ranking M Bus terminal X5 and forward ed to the M Bus 2 Reply Red Data is being received from the M Bus and forwarded to the RS 232 interface or the hig...

Page 15: ...the M Bus is transferred for further processing via the RS 232 interface to a PC with ADICOS software M BUS Repeater If the setting Operation via M Bus input was selected the ADICOS M BUSMASTER XF wor...

Page 16: ...Description of Product 11 ADICOS M BUSMASTER XF 420 2410 003 EN20 3 6 Fuses F3 F2 F1 Fig 6 F1 Mains fuse 230 V 1 A slow blow F2 Mains fuse 24 V 4 A slow blow F3 Output fuse M Bus 2 5 A slow blow...

Page 17: ...rained personnel may perform installation work Deenergize the entire detector system before performing any type of instal lation work 5 1 Requirements of Mounting Location The ADICOS M BUSMASTER XF is...

Page 18: ...COS M BUSMASTER XF can cause malfunction ing leading to failure of the fire detection system Only properly trained personnel may wire the equipment Deenergize the entire detector system before perform...

Page 19: ...ecure the ADICOS M BUSMASTER XF with suitable fittings Consider the wall structure and the thickness of the enclosure when choosing fittings Chap 10 1 Dimensions 3 Connect the components to one anothe...

Page 20: ...switched on The green LED normal should light up to indicate that the device is ready for operation There should be voltage of approx 40 V at the output terminals of the ADICOS M BUSMASTER XF Once the...

Page 21: ...equipped with an Ethernet connection upon request The network card is based on a module XPort supplied by Lantronix The MAC address of the network card can be found on the label on the XPort 1 2 xxx x...

Page 22: ...Lantronix DeviceInstaller on a computer in the same network Z The software automatically lists all Ethernet modules within the network as XPort Direct or XPort Direct Fig 10 Changing IP Address 1 Sele...

Page 23: ...18 ADICOS M BUSMASTER XF 420 2410 003 EN20 Commissioning Fig 12 4 Enter the desired IP address and the subnet mask then click Next Fig 13 5 Click Assign Z The new IP address is programmed Fig 14...

Page 24: ...position Refer to Chap 3 5 1 Jumper Settings Interface A0 A1 1 Adjust the interface parameters in the software as follows Fig 15 Bus connection Ethernet TCP IP TCP IP setting the preset or programmed...

Page 25: ...rectly ADICOS equipment works with electric current Failure to clean the equipment properly can lead to electric shock Deenergize the entire detector system before cleaning the device The ADICOS M BUS...

Page 26: ...supply to de tector s is disrupted No connection to the service PC Defect in M BUS MASTER Check M Bus voltage Check bus lines for breakage disruptions Measure voltage at M Bus output set point 35 38 V...

Page 27: ...Bus 2 5 A slow blow Power output M Bus 60 W internal output current limited to 1 5 A Baud rate M Bus 4800 baud Maximum line length M Bus 2 km 4800 baud Maximum line length RS 232 2 5 m Max number of d...

Page 28: ...1 Dimensions 200 280 303 163 265 72 5 Fig 8 11 Disposal Return the device to the manufacturer when it reaches the end of its serviceable life The manufacturer will ensure that the components are dispo...

Page 29: ...24 ADICOS M BUSMASTER XF 420 2410 003 EN20 Disposal...

Reviews: