LF_FF_RawSetDataSizeNotCorrect
The size of the written set data is not correct.
LF_FF_RawSetDataCRCerror
A CRC error occurred while transferring the raw set data.
This feature is automatically updated if any of the following features is changed:
LF_FF_RawSetDataEnd, LF_FF_RawSetDataReadStart, LF_FF_RawSetDataWriteStart
7.18 User set control
At delivery, the factory settings are stored as the power-up default settings. The user may however change the
power-up settings without losing the factory default settings. Therefore a copy of the factory default settings is
stored in the camera.
7.18.1 UserSetSelector |
RW
|
B
|
Default
This is the factory default set. The user cannot change this set.
UserSet1
This is the set the user can save. This set is automatically loaded at power
up.
This feature is automatically updated if any of the following features is changed:
UserSetLoad, UserSetSave
Table 7-7 lists the features and their default values that are stored in the factory default set.
7.18.2 UserSetLoad |
WO
|
B
|
command
Activate the set that is selected with UserSetSelector.
NOTE:
Loading a set requires acquisition to be stopped.
7.18.3 UserSetSave |
WO
|
B
|
Command
If UserSet1 is selected in the UserSetSelector, this feature can be used to