PARAMETER NAME
INTERFACE
ACCESS
VISIBILITY
RANGE
DEFAULT
DarkFieldCorrectionEnable
Iboolean
R/W
B
BrightFieldCorrectionEnable
Iboolean
R/W
B
CalibrationTypeSelector
enumeration
RW
E
AverageBlackLevelCali-
bration,
FullDarkFieldCalibra-
tion,
IncrementalDarkField-
Calibration,
GainCalibration
FullDark-
FieldCali-
bration
CalibrationFlatFieldExecute
command
WO
E
CalibrationFlatFieldExecute-
Abort
command
WO
E
CalibrationFlatFieldSetSelec-
tor
enumeration
RW
E
FlatFieldInputSet,
GainCalibrationSet1,
GainCalibrationSet2,
GainCalibrationSet3,
GainCalibrationSet4
CalibrationFlatFieldMode
enumeration
RW
E
LocalGainCorrection,
GlobalGainCorrection
LocalGain-
Correction
CalibrationFlatFieldAdjust-
Mode
enumeration
RW
E
NoAdjust,
AutoLevelAdjust
AutoLevel-
Adjust
CalibrationFlatFieldExposure-
SetPoint
IInteger
RW
E
50 to 1023
700
CalibrationFlatFieldStatus
enumeration
RO
E
Done,
FullDarkFieldOffsetCali-
brationPending,
IncrementallDarkField-
OffsetCalibrationPend-
ing,
GainCalibrationPend-
ing,
LoadOrSaveCalibra-
tionPending
CalibrationFlatFieldError-
Result
enumeration
RO
E
NoError,
StartCalibrationWhi-
leCalibrationIsPending,
CRC_ErrorDuringRead-
OfFlatFieldData,
RatioMaximumOver-
MinimumError,
AcquisitonModeNot-
ContinuousError,
SensorExposure-
TooLowError,
SensorExposure-
TooLowHigh,
SensorExposureInsta-
bleError,
NotAllowedCombina-
tion,
InternalCamera_Tim-
eout_Error
CalibrationFlatFieldMinimum-
Value
integer
RO
E
CalibrationFlatFieldMaxi-
mumValue
integer
RO
E