User Manual MIC 980
Issue 21.01.2019_01
28
Be aware: Administrators
If administrators have been assigned in the controller, a password will be required before
you can change a nominal value. Only an administrator with the user right „Nominal value
change/ skip into next step“ can change nominal values.
8.3.2
Optional displays during operation
All other optional displays are identical to the displays in readiness mode, see items 7.1.3 to 7.1.6
8.4 Shut-down conditions
When at least one of the shut-down conditions has been met, the program step will be terminated. If a
particular nominal value has not been pre-programmed
(zero or OFF),
then the attached shut-down
condition is disabled.
Shut-down conditions are:
The nominal step time has run out and is 00.00
Unscheduled shut-down:
Pressing the „Stop“ button will terminate a program
Chamber sensor defect generally terminates a program
Be aware
An empty (invalid) program step will be terminated immediately or not even started. A
program step is considered valid when at least on process has been pre-programmed.
8.5 Transient changes to the nominal values
In standby mode the nominal values can be transiently changed. This means the new nominal values
are only valid for the current step and are not saved.
Press the relevant nominal value box and use the numerical pad that will appear to enter the new value.
Confirm with „Enter“.
9
Pause mode
A program can be pause by a disruption or a manual change made by a user. There is no temperature
control in pause mode. The baking time, steam time and flap time are not counted. The reason for pause
mode is shown on the info bar/status bar. All regular
1
controller outputs (Relays, analogue outputs) are
switched off.
Shortcut buttons / Operating mode
1. Air circulation level off
2
2. Steam flap off
3. Turntable off
3
4. Resume program
5. Menu (item 3)
6. Light off
7. Extractor (exhaust fan) off
8. Terminate all operations. Back to
readiness mode (see item 7)
Informationsleiste
Operating mode display (is flashing)
In pause mode the reason for pausing the
program will also be shown.
1
An exception can be outputs that have been configured as event–related outputs, e.g. light when the door is
opened.
2
Manual switch-on possible. Manual activation is shown by the „M“ in the button.
3
Manual approach of the end position is possible.
1
2
3
4
5
6
7
8