11
IF IN THE UNLIKELY EVENT THAT A
PRESSURIZED FIXTURE RESULTS IN
CATASTROPHIC LENS FAILURE, EYE
PROTECTION MUST BE WORN AT ALL
TIMES WHEN USING ADJ IP TESTER,
ESPECIALLY WITH FIXTURES FEATURING
LARGE GLASS LENSES. ALSO, TO PROTECT
HANDS FROM ANY SHARP FRANGIBLE
MATERIAL, THE USE OF CUT RESISTENT
GLOVES IS ALSO HIGHLY RECOMMENDED.
TO R Q U E S E T T I N G S F O R S C R E W S
ALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. All screws are Allen Head screws.
Please see below for screw locations.
TORQUE DRIVERS
(Recommended): UTICA
TS-30 (Shown)
ALTERNATIVE DRIVERS:
Proto J6107A
Wiha 28887
Encore Burst UV IP Testing Parameters
Vacuum(KPA)
Hold time(S)
Pressure(KPA)
Hold time(S)
-50KPA
60S
13KPA
60S
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE
ISSUES! TO CONFIRM THE IP65 INTEGRITY AFTER MAINTENANCE, TEST THE
FIXTURE USING THE ADJ IP TESTER. CONTACT ADJ SERVICE FOR MORE DETAILS.