A.D.J. Supply Europe B.V.
– www.americandj.eu – Ikon Profile WW Instruction Manual Page 7
SYSTEM MENU (continued)
DNST
- This mode can be used as a precaution mode, that in case the DMX signal is lost, interrupted,
or power is lost, the operating mode chosen in the setup is the running mode the fixture will go into
when the DMX signal is lost. You can also set this as the operating mode you would like the unit to
return to when power is applied.
1. Press the MENU button until “
DNST
” is displayed, and either “
MASL
”, “
BLND
”, or “
LAST
” will be displayed
beneath.
2. Press ENTER and the bottom choice will begin to flash. Use the UP or DOWN buttons to choose an
operating mode you would like the unit to start up in when power is applied or the DMX signal is lost.
•
MASL
(Master Slave) - If the DMX signal is lost or power is applied, the unit will automatically go into Master
Slave mode and run a built-in show.
•
BLND
(Blackout) - If the DMX signal is lost or interrupted, the unit will automatically go into stand by mode.
•
LAST
- If the DMX signal is lost the fixture will stay in the last DMX setting. If power is applied and this mode
is set, the unit will automatically go into the last DMX set up.
3. Press ENTER to confirm your desired set up.
DIND
- This will let select your desired dimmer curve.
1. Press the MENU button until “
DIND
” is displayed, and press ENTER. 1 of 5 dimmer curves will be displayed.
“
STDA
” (standard), “
STGE
” (stage), “
TV
” (TV), “
ARAL
” (Architectural), or “
THAL
” (Theatre). See the dimmer
curve chart on page 10 for more info.
2. Press the UP or DOWN buttons to find your desired dimmer curve and press ENTER to confim and exit
LED
- With this function the LED display will turn off after 2 minutes.
1. Press the MENU button until “
LED
” is displayed, press ENTER.
2. The display will show either “
ON”
or
“OFF
”. Press the UP or DOWN buttons to select “
ON
” to keep the LED
display on at
all times, or “
OFF
” to allow the LED display to turn off after 2 minutes. Press any button to turn on
the LED display again.
3. Press ENTER to confirm and exit.
DISP
- This function will reverse the display 180º.
1. Press the MENU button until “
DISP
” is displayed, press ENTER.
2. Press the UP button to select “
DISP
” to activate this function, or “
DSIP
” to deactivate this function.
3. Press ENTER to confirm.
MANU
- In this submenu you are able to test the dimmer, and strobe.
1. Press the MENU button until “
MANU
” is displayed, press ENTER.
2. Use the UP and DOWN buttons to scroll through the various functions able for testing. Once you have found
your desired function you would like to test press ENTER.
3. After you have pressed ENTER, use the UP and DOWN buttons to adjust the values and test the function.
To exit press the MENU button.
TEST
- This function will run a self test program.
1. Press the MENU button until “
TEST
” is displayed, press ENTER.
2. The fixture will now run a self test.
TEMP
- With this function you can check the temperature of the fixture.
1. Press the MENU button until “
TEMP
” is displayed, press ENTER.
2. The fixture temperature will now be displayed. Press MENU to exit.
FHRS
- With this function you can display the running time of the unit.
1. Press the MENU button until “
FHRS
” is displayed, press ENTER.
2. The display shows the running time of the unit. Press MENU to exit.
VER
- Use this function to display the Software version of the unit.
1. Press the MENU button until “
VER
” is displayed, press ENTER.
2. The display will show the software version.