background image

ADJ Products, LLC  -  www.adj.com  - Par Z Move User Manual Page 5

  

Par Z Move

                                                                                    

Safety Precautions

•   Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to   

   remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6”  

 

   (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to be walked on or pinched by  

 

   items placed upon or against them, paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 23    

   for cleaning details.

•   Heat -The appliance should be situated away from heat sources such as radiators, heat registers,    

   stoves, or other appliances (including amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the fixture.

    C. The fixture does not appear to operate normally or exhibits a marked change in performance.

    D. The fixture has fallen and/or subjected to extreme handling.

Summary of Contents for PAR Z MOVE

Page 1: ...User Instructions PAR Z MOVE...

Page 2: ...Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interfe...

Page 3: ...arranty Registration Safety Precautions Installation Overview DMX Set Up DMX Addressing DMX Channel Modes Values System Menu Operating Instructions Dimmer Curve Chart Dimensional Drawings Power Linkin...

Page 4: ...odes 7 9 11 This product is intended to be used by professionally trained personnel only and is not suitable for private use Customer Support Contact ADJ Service for any product related service and su...

Page 5: ...lso be written down on a piece of paper included in the shipping carton If the unit is under warranty you must provide a copy of your proof of purchase invoice You may obtain a R A number by contactin...

Page 6: ...s unit if it becomes damaged During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not l...

Page 7: ...ms animation wheels frost filters iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific only to ADJ lighting fixtures it is a common issue with lighting fixtures from a...

Page 8: ...Never use the carrying handles for secondary attachment When installing the unit the trussing or area of installation must be able to hold 10 times the weight without any deformation When installing t...

Page 9: ...y cable attachment points located on the base plate and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw NOTICE The suitable enviromental te...

Page 10: ...C www adj com Par Z Move User Manual Page 9 Par Z Move Overview LED Display Mode Button Enter Button Up Button Down Button Service Port 5 Pin XLR In 3 Pin XLR In 5 Pin XLR Out 3 Pin XLR Out powerCON I...

Page 11: ...n be controlled via DMX 512 protocol The Par Z Move has 3 DMX channel modes The DMX address is set on the front panel of the Par Z Move Your unit and your DMX controller require either a standard 3 pi...

Page 12: ...n reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last f...

Page 13: ...Setting all fixtures to the same DMX address will cause all fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If you se...

Page 14: ...DIMMER 0 100 3 5 6 000 255 000 031 032 063 064 095 096 127 128 159 160 191 192 223 224 255 STANDARD STAGE TV ARCHITECTURAL THEATRE STAGE 2 DIMMER SPEED FAST SLOW 0 1 10S DEFAULT TO UNIT SETTING 000 0...

Page 15: ...Control Settings Reverse Pan Motion Sleep Setting No Activity Dim Modes Dimming Curve Modes Dimming Speed Standard Stage TV Architectural Theatre Stage2 Dim Speed 0 1S 10S LED Refresh Rate 900Hz 1000H...

Page 16: ...Resettable LED On Running Time Resettable Reset LED Running Time Maximum Temperature Reached Resettable Reset Temperature Maximum Temperature Reached Not Resettable Fan Info RPM Base_Fan XXX LED_Fan...

Page 17: ...ed DMX channel mode and press ENTER to confirm your setting Press the MENU button to exit without any changes No DMX Status This mode is used as a precaution mode In case the DMX signal is lost or int...

Page 18: ...ll activate tilt inverse NO will deactivate the function 4 Press the ENTER button to confirm your setting or press the MENU button to exit P T Feedback With this function you have the pan and tilts po...

Page 19: ...ess ENTER 3 Use the UP or DOWN buttons to scroll through the settings 4 Press the ENTER button to confirm your setting or press the MENU button to exit Dim Modes This will let select your desired dimm...

Page 20: ...4 Activate and deactivate the display control panel lock 1 Access the main menu and press the UP or DOWN buttons so that Personality is highlighted then press ENTER 2 Use the UP or DOWN buttons to swi...

Page 21: ...s Download the software update to a flash stick and plug the flash stick into the Flash Drive slot located on the front of the unit Contact ADJ customer service for help when updating software Factory...

Page 22: ...r DOWN buttons until Fixture Life Time is highlighted and press ENTER 3 Press the UP or DOWN buttons until P On Time R is highlighted and press ENTER 4 The power ON running time of the fixture will no...

Page 23: ...N buttons to set the pass code to 50 and press ENTER The LED ON TIME R will now be reset to 0 Current With this function you can check the current temperature of the LED 1 Access the main menu and pre...

Page 24: ...highlighted and press ENTER 3 Press the UP or DOWN buttons until Reset LED Temps is highlighted and press ENTER 4 Use the UP or DOWN buttons to set the pass code to 50 and press ENTER The MAX RESETTA...

Page 25: ...buttons so that Information is highlighted then press ENTER 2 Press the UP or DOWN buttons until Max Temp LED ON is highlighted and press ENTER 3 The fixtures current LED On temperature will now be di...

Page 26: ...me ms 0 Sec 255 255 0 0 Standard default 0 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Stage 2 0 1100 0 1660 Rise Time ms Down T...

Page 27: ...ADJ Products LLC www adj com Par Z Move User Manual Page 26 Par Z Move Dimensional Drawing 12 05 306mm 8 22 209mm 8 6 218mm 17 63 448mm...

Page 28: ...to the PCB is broken Due to fog residue smoke and dust cleaning the internal and external optical lenses must be car ried out periodically to optimize light output 1 Use normal glass cleaner and a so...

Page 29: ...b all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of t...

Page 30: ...White COB LED Working Position Any safe working position Power Draw 250W Dimensions 12 05 L x 8 6 W x 17 63 H 306 x 218 x 448mm Weight 25lbs 11 3 kgs DMX Channels 3 DMX Modes 7 9 11 Warranty 2 Year 73...

Reviews: