42
BIOS Settings
cPCI-3600 Series
security is disabled, the system will boot and setup can be
accessed.
Remote Console Function
Enables remote access through POST messages and commands
through serial-port access.
Console Redirection
Enables/Disables the remote Console Function: The default value
is Enabled.
Baud Rate
When Console Redirection is Enabled, the BIOS will allow users
to set the serial port's operating baud rate. Options: 9600 bps,
19200 bps, 38400 bps, 57600 bps, and 115200 bps
Agent Connect via
Enables direct connection mode. The ETX-GLX BIOS only sup-
ports NULL mode (connecting two computers to a null modem for
direct connection).
Agent Wait Time (min.)
Select the amount of time (min.) to wait for a successful connec-
tion. If the time limit is exceeded, the ETX-GLX will not communi-
cate with its remote host.
Agent After Boot
Monitors text-based applications (such as DOS) after POST. The
default setting is Disabled.
NOTE:
NOTE:
Remote Console is a character-based terminal applica-
tion. It supports either VT100 or ANSI terminals. It does
not support graphics or graphical user interfaces.
NOTE:
NOTE:
The Baud Rate settings between the ETX-GLX and its
monitoring computer must be the same. If they are differ-
ent, an error message, "Award Preboot Agent Installa-
tion Failed" will display and the equipment will not
properly communicate.