background image

viii

List of Tables

Leading

EDGE COMPUTING

This page intentionally left blank.

Summary of Contents for EGX-MXM-RTX3000

Page 1: ...Leading EDGE COMPUTING EGX MXM RTX3000 NVIDIA Turing TU106 Quadro RTX3000 Embedded Graphics Module User s Manual Manual Rev 1 0 Revision Date April 21 2021 Part No 50M 00021 1000 ...

Page 2: ...ii Revision History Leading EDGE COMPUTING Revision History Revision Release Date Description of Change s 0 1 2021 04 21 Initial release ...

Page 3: ... of the use or inability to use the product or documentation even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsi bility to global environmental preservation through compliance with the European Union s Restriction of Hazardous Substances RoHS directive and Waste Electrical and Electronic Equipment WEEE directive Environ...

Page 4: ...e harm For more information go to www P65Warnings ca gov Trademarks Product names mentioned herein are used for identification pur poses only and may be trademarks and or registered trademarks of their respective companies Conventions Take note of the following conventions used throughout this manual to make sure that users perform certain tasks and instructions properly NOTE NOTE Additional infor...

Page 5: ...ions 3 1 3 3 Software Support 3 1 3 4 Graphics Options 3 1 4 Functional Block Diagram 4 1 5 Mechanical Layout 5 1 6 MXM Connector Pin Definitions 8 1 7 Thermal Policy 13 1 8 Unpacking Checklist 13 2 System Requirements 15 2 1 Power Sequencing 15 2 2 Module Power Up and Down 16 2 3 Reset Requirements 16 2 4 Dual Mode DisplayPort Implementation 17 2 5 DVI HDMI on DisplayPort Interface 18 2 6 Driver ...

Page 6: ...vi Table of Contents Leading EDGE COMPUTING Important Safety Instructions 21 Getting Service 23 ...

Page 7: ...List of Tables vii EGX MXM RTX3000 List of Tables Table 1 1 Graphics Module Display Options 3 Table 1 2 NVIDIA Link Display Types 3 Table 1 3 MXM Connector Pin Definitions 8 Table 1 4 Thermal Policy 13 ...

Page 8: ...viii List of Tables Leading EDGE COMPUTING This page intentionally left blank ...

Page 9: ...imensions 5 Figure 1 3 EGX MXM RTX3000 Layout Top and Side Views 6 Figure 1 4 EGX MXM RTX3000 Layout Bottom View 7 Figure 1 5 MXM Connector 7 Figure 2 1 Power Sequencing 15 Figure 2 2 Module Power Down 16 Figure 2 3 Reset Sequencing 16 Figure 2 4 Dual Mode DisplayPort Implementation 17 Figure 2 5 DVI HDMI on DisplayPort Interface 18 ...

Page 10: ...x List of Figures Leading EDGE COMPUTING This page intentionally left blank ...

Page 11: ...s suitable for embedded rugge dized or mobile system designs With its 1920 CUDA core Turing GPU and additional 240 Tensors Cores the EGX MXM RTX3000 supports 4 FHD displays delivering the latest leading edge GPU performance for your embedded system with AI capabilities enabled Its superior graphics performance GPU computing and video capabilities are the ideal solution for systems such as digital ...

Page 12: ...ort 1920 CUDA cores 5 3 TFLOPS SP Peak CUDA Toolkit 8 0 CUDA Compute version 6 1 OpenCL 1 2 DirectX 12 OpenGL 4 6 Vulcan 1 0 Memory GDDR6 Memory 6GB 14Gbps 7GHz Configuration 256Mb x32 Bandwidth 128 bit 336 GB s data rate x32 GDDR6 DRAM device data width Status LED Color Yellow Normal Red Abnormal Physical Dimensions 82 W x 105 D x 4 8 H mm Locking Mechanism Standard MXM 3 1 Type B Environmental O...

Page 13: ...w Table 1 1 Graphics Module Display Options Table 1 2 NVIDIA Link Display Types DisplayPort X 1 2 1 3 1 4 X Max pixel clock 1050 MP s X Max bandwidth 25 9 GB s connector HDMI 2 0 Max resolution 4096 x 2160 at 60 Hz HDCP Support 1 3 DP 2 2 DP HDMI MXM port DP_A DP_B DP_C DP_D NVIDIA Link Link C Link A Link E Link F Link Display Type Link A DisplayPort DVI Single Link or Dual Link with Link B Link B...

Page 14: ...hen virtual link DP1 4 DP1 4 Power Management PWR_EN PWR_GOOD WAKE PM I2CS JTAG SPI SPI SPI VBIOS 1GB x6 pcs GDDR6 Total 6GB GDDR6 BW 256b 14Gbps 2CH x256M x16 I O Power Supply Power Supply NVVDD PH2 NVVDD PH3 NV3V3 NVVDD PH1 Power Supply FBVDD PH1 Power Supply PEX_VDD Power Supply VDD_AON MAIN IFPF DP1 4 NVVDD PH4 NVVDD PH5 NVVDD PH6 FBVDD PH2 DP_B LVDS_L DP_A DP_C DP_D NVIDIA Quadro RTX3000 GPU ...

Page 15: ...Introduction 5 EGX MXM RTX3000 1 5 Mechanical Layout Figure 1 2 EGX MXM RTX3000 Dimensions NOTE NOTE All dimensions shown are in mm 82 105 ...

Page 16: ...1 50 75 8 25 54 25 15 65 29 08 42 57 61 89 3 41 31 26 17 79 44 71 31 25 28 50 B C D B C C C Top Side 1 20 2 90 0 85 A 45 10 0 18 A Section Scale 2 1 6 3 20 B Section Scale 2 1 PTH Hole 2 pcs 3 20 6 C Section Scale 2 1 PTH Hole 4 pcs Top Side OD 6 0mm ID 3 2mm Bottom Side OD 7 0mm ID 3 2mm 3 75MIN 1 1 25 0 50 0 50 1 25 D Section Scale 2 1 1 0 50 0 50 1 E Section Scale 2 1 ...

Page 17: ... Figure 1 4 EGX MXM RTX3000 Layout Bottom View Figure 1 5 MXM Connector 3 10 2x4 82 2 35 1 85 129x0 35 0 0 28 75 31 34 74 39 76 E B B C C C C Bottom Side Pin 281 R G5 X G6 Pin 133 Pin 125 Pin 134 Pin 124 Pin E3 Pin E1 Pin E4 Pin E2 ...

Page 18: ...V 8 PWR_EN 9 5V 10 27MHZ_REF 11 GND 12 GND 13 GND 14 RSVD 15 GND 16 RSVD 17 GND 18 PWR_LEVEL 100K PU to 3 3V 19 RSVD 20 TH_OVERT 100K PU to 3 3V 21 RSVD 22 TH_ALERT 100K PU to 3 3V 23 RSVD 24 RSVD 25 RSVD 26 RSVD 27 RSVD 28 RSVD 29 RSVD 30 RSVD 31 RSVD 32 SMB_DAT 100K PU to 3 3V 33 RSVD 34 SMB_CLK 100K PU to 3 3V 35 RSVD 36 GND 37 GND 38 RSVD 39 RSVD 40 RSVD 41 RSVD 42 RSVD 43 RSVD 44 RSVD 45 RSVD...

Page 19: ... GND 72 PEX_TX11 73 PEX_RX11 74 PEX_TX11 75 PEX_RX11 76 GND 77 GND 78 PEX_TX10 79 PEX_RX10 80 PEX_TX10 81 PEX_RX10 82 GND 83 GND 84 PEX_TX9 85 PEX_RX9 86 PEX_TX9 87 PEX_RX9 88 GND 89 GND 90 PEX_TX8 91 PEX_RX8 92 PEX_TX8 93 PEX_RX8 94 GND 95 GND 96 PEX_TX7 97 PEX_RX7 98 PEX_TX7 99 PEX_RX7 100 GND 101 GND 102 PEX_TX6 103 PEX_RX6 104 PEX_TX6 105 PEX_RX6 106 GND Primary Side bottom side Secondary Side...

Page 20: ...Y 132 KEY 133 GND 134 GND 135 PEX_RX2 136 PEX_TX2 137 PEX_RX2 138 PEX_TX2 139 GND 140 GND 141 PEX_RX1 142 PEX_TX1 143 PEX_RX1 144 PEX_TX1 145 GND 146 GND 147 PEX_RX0 148 PEX_TX0 149 PEX_RX0 150 PEX_TX0 151 GND 152 GND 153 PEX_REFCLK 154 PEX_CLK_REQ 155 PEX_REFCLK 156 PEX_RST 157 GND 158 RSVD 159 RSVD 160 RSVD 161 RSVD 162 RSVD 163 RSVD 164 RSVD 165 RSVD 166 GND Primary Side bottom side Secondary S...

Page 21: ...D 194 RSVD 195 RSVD 196 RSVD 197 GND 198 GND 199 DP_C_L0 200 RSVD 201 DP_C_L0 202 RSVD 203 GND 204 GND 205 DP_C_L1 206 DP_D_L0 207 DP_C_L1 208 DP_D_L0 209 GND 210 GND 211 DP_C_L2 212 DP_D_L1 213 DP_C_L2 214 DP_D_L1 215 GND 216 GND 217 DP_C_L3 218 DP_D_L2 219 DP_C_L3 220 DP_D_L2 221 GND 222 GND 223 DP_C_AUX 224 DP_D_L3 225 DP_C_AUX 226 DP_D_L3 Primary Side bottom side Secondary Side top side Pin Si...

Page 22: ...D 251 GND 252 DP_B_L1 253 DP_A_L0 254 DP_B_L1 255 DP_A_L0 256 GND 257 GND 258 DP_B_L2 259 DP_A_L1 260 DP_B_L2 261 DP_A_L1 262 GND 263 GND 264 DP_B_L3 265 DP_A_L2 266 DP_B_L3 267 DP_A_L2 268 GND 269 GND 270 DP_B_AUX 271 DP_A_L3 272 DP_B_AUX 273 DP_A_L3 274 DP_B_HPD PD 100K 275 GND 276 DP_A_HPD PD 100K 277 DP_A_AUX 278 3V3 279 DP_A_AUX 280 3V3 281 PRSNT_L 0 ohm PD Primary Side bottom side Secondary ...

Page 23: ...terials for inspection Obtain authorization from your dealer before returning any product to ADLINK Ensure that the fol lowing items are included in the package X EGX MXM RTX3000 embedded graphics module Parameter Value Units Thermal Resistance Junction to Case RJC 0 017 C W Thermal Resistance Junction to PCB Board RJB 0 96 C W GPU Maximum Operating Temperature1 89 C GPU Slowdown Temperature THERM...

Page 24: ...14 Introduction Leading EDGE COMPUTING This page intentionally left blank ...

Page 25: ...irements 15 EGX MXM RTX3000 2 System Requirements 2 1 Power Sequencing For initial power on or to Resume from S3 and S4 this sequence must be followed Figure 2 1 Power Sequencing TPV PE PV TPE PG PV TPV PE TPE PG ...

Page 26: ...an decide whether to keep the module input power when the MXM module is powered down Figure 2 2 Module Power Down 2 3 Reset Requirements Figure 2 3 Reset Sequencing MODULE INPUT POWER PWR_EN MODULE INTERNAL POWER PWR_GOOD TPVPERL TPERST PG TPERST CLK TFAIL TPVPERL PV TPERST CLK V TPERST PG V TFAIL QV MODULE INPUT POWER PWR_EN PWR_GOOD PEX_REFCLK PEX_RST ...

Page 27: ...y Support and Options on page 3 The system requires a switch circuit to determine whether the AUX or DDC signal is output from the MXM module and AC coupling capacitors should be placed on the sys tem board Figure 2 4 Dual Mode DisplayPort Implementation DisplayPort Connector MXM Connector 3 3V AUX_P DDC_CLK AUX_N DDC_DAT DP_x_Lx_P DP_x_Lx_N CONFIG1 CABLE ADAPTOR DETECT Hot Plug Detect ...

Page 28: ...0p supported Two 499Ω 1 pulldown resistors to ground on the DP lanes must placed on the DVI HDMI connector side of the AC coupling gated by a MOSFET to limit leakage Please contact your local ADLINK technical support rep resentative for HDMI DVI support Figure 2 5 DVI HDMI on DisplayPort Interface 3 3V 3 3V Hot Plug Detect AUX_P DDC_CLK AUX_N DDC_DAT MXM Connector Level Shifter DVI HDMI Connector ...

Page 29: ...m https www adlinktech com Products Embedded_Graphics Embedded_MXM_Modules EGX MXM RTX3000 2 7 Certifications Agencies X Windows Hardware Quality Lab WHQL certified for Windows 10 X EU Reduction of Hazardous Substances EU RoHS X Conformité Européenne CE X Federal Communications Commission FCC ...

Page 30: ...20 System Requirements Leading EDGE COMPUTING This page intentionally left blank ...

Page 31: ...t temperature of 50ºC X When installing mounting or uninstalling removing device or when removal of a chassis cover is required for user ser vicing Z Turn off power and unplug any power cords cables Z Reinstall all chassis covers before restoring power X To avoid electrical shock and or damage to device Z Keep device away from water or liquid sources Z Keep device away from high heat or humidity Z...

Page 32: ...re loosening the thumbscrews and always fasten the thumbscrews with a screwdriver before starting the system up X It is recommended that the device be installed only in a server room or computer room where access is Z Restricted to qualified service personnel or users familiar with restrictions applied to the location reasons therefor and any precautions required Z Only afforded by the use of a to...

Page 33: ... 1 408 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology GmbH Hans Thoma Strasse 11 D 68163 Mannheim Germany Tel 49 621 43214 0 Fax 49 621 43214 30 Email emea adlinkt...

Reviews: