4-4 Data Format
4. 5. Summary of Data Format
The following table shows the relation between the output range
setting with the data format and the resolution.
Code
Output
Range
Data Format
Maximum
Value
Minimum
Value
Output
Resolution
30
0 to 20 mA
Eng. Units
20.000
00.000
4.88
µ
A
31
4 to 20 mA
Eng. Units
20.000
04.000
4.88
µ
A
32
0 to 10 V
Eng. Units
10.000
00.000
2.442 mV
Code
Output
Range
Data Format
Maximum
Value
Minimum
Value
Output
Resolution
30
0 to 20 mA
% of FSR
100.00
000.00
4.88
µ
A
31
4 to 20 mA
% of FSR
100.00
000.00
4.88
µ
A
32
0 to 10 V
% of FSR
100.00
000.00
2.442 mV
Code
Output
Range
Data Format
Maximum
Value
Minimum
Value
Output
Resolution
30
0 to 20 mA
Hexdecimal
FFF
000
4.88
µ
A
31
4 to 20 mA
Hexdecimal
FFF
000
4.88
µ
A
32
0 to 10 V
Hexdecimal
FFF
000
2.442 mV