Command Set
3.14 Offset Calibration to each Channel
@Description
To correct the offset errors of AD converter by using the offset
calibration.
@Syntax
$(Addr)1(Channel No)<CR>
$
Command leading code
(Addr)
Address ID
1
Offset calibration.
(Channel No)
Channel for calibration.
(1 character)0~2
@Response
!(Addr)<CR>
or
?(Addr)<CR
>
!
Command is valid.
?
Command is invalid.
(Addr)
Address ID.
@Example
User command:
$0612<CR>
Response:
!06<CR>
To perform the offset calibration for analog input module ND-6013
channel 2 at specified address 06 (Hex).
Note:
To perform the calibration, a proper input signal should be
connected to the analog input module. Different input range
have different input voltage, detail refer chapter 5
“
Calibration
” .
(6013)
(for 6013 F/W version
A3.05~A4.60)