background image

BIOS Setup

 41

NuPRO-A40H

5.2

Main Setup

When you first enter the Setup Utility, you will enter the Main setup
screen. You can always return to the Main setup screen by select-
ing the Main tab. There are two Main Setup options. They are
described in this section. The Main BIOS Setup screen is shown
below.

System & Board Info

BIOS Vendor 

Displays the BIOS vendor.

Core Version

Displays the BIOS core version.

BIOS Version

Display the current BIOS revision.

Build Data and Time

Displays the BIOS build data. 

Total Memory

Display the current system total memory.

Summary of Contents for NuPRO-A40H

Page 1: ...Advance Technologies Automate the World Manual Rev 2 00 Revision Date September 11 2013 Part No 50 13072 1010 NuPRO A40H Full Size PICMG 1 0 Intel Core i7 i5 i3 LGA1155 SHB User s Manual ...

Page 2: ...ii Revision History Revision History Revision Release Date Description of Change s 1 00 2013 07 19 Preliminary release 2 00 2013 09 11 Initial release add BIOS WDT system resources ...

Page 3: ...even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the Euro pean Union s Restriction of Hazardous Substances RoHS direc tive and Waste Electrical and Electronic Equipment WEEE directive Environmental protection is a top priority for ADLINK We have enfor...

Page 4: ...er 2 Hardware Information Provides technical informa tion on connectors and jumpers for configuring the NuPRO A40H Chapter 3 Getting Started Illustrates how to install components on the NuPRO A40H such as CPU heatsink and memory mod ules Chapter 4 Driver Installation Provides information on how to install the NuPRO A40H device drivers Chapter 5 BIOS Setup Describes basic navigation for the AMIBIOS...

Page 5: ...erly NOTE NOTE Additional information aids and tips that help users perform tasks CAUTION Information to prevent minor physical injury component dam age data loss and or program corruption when trying to com plete a task WARNING Information to prevent serious physical injury component damage data loss and or program corruption when trying to complete a specific task ...

Page 6: ...vi Preface This page intentionally left blank ...

Page 7: ...am 5 1 5 Functional Description 6 1 6 Mechanical Drawing 8 1 7 I O Connectivity 9 1 8 Power Consumption 10 1 9 Package Contents 11 2 Hardware Information 13 2 1 Rear Panel I O Ports 13 2 2 Board Layout 15 2 3 Onboard Connectors 16 2 4 Jumpers 24 3 Getting Started 27 3 1 Installing the CPU 27 3 2 Installing the CPU Fan and Heatsink 31 3 3 Installing Memory Modules 32 3 4 Installing the Power Connec...

Page 8: ...5 3 4 USB Configuration 48 5 3 5 Super IO Configuration 50 5 3 6 Serial Port Console Redirection 51 5 3 7 CPU PPM Configuration 55 5 4 Chipset Setup 56 5 4 1 PCH IO Configuration 57 5 4 2 System Agent SA Configuration 60 5 5 Boot Configuration 63 5 6 Security Setup 66 5 7 System Management 68 5 8 Exit Menu 69 A Appendix Watchdog Timer 71 A 1 Sample Code 71 B Appendix System Resources 75 B 1 System...

Page 9: ...Table of Contents ix NuPRO A40H Important Safety Instructions 83 Getting Service 85 ...

Page 10: ...x Table of Contents This page intentionally left blank ...

Page 11: ...List of Figures xi NuPRO A40H List of Figures Figure 1 1 NuPRO A40H Block Diagram 5 Figure 1 2 NuPRO A40H Board Dimensions 8 Figure 2 1 Rear Panel I O Ports 13 Figure 2 2 Connectors and Jumpers 15 ...

Page 12: ...xii List of Figures This page intentionally left blank ...

Page 13: ...ble 1 2 Core i7 3770 Processor Power Consumption 10 Table B 1 System Memory Map 75 Table B 2 Direct Memory Access Channels 75 Table B 3 IO Map 77 Table B 4 IRQ Lines PIC Mode 78 Table B 5 IRQ Lines APIC Mode 79 Table B 6 PCI Configuration Space Map 80 Table B 7 PCI Interrupt Routing Map 81 ...

Page 14: ...xiv List of Tables This page intentionally left blank ...

Page 15: ...pplications The NuPRO A40H supports 22nm process CPUs at up to 3 4 GHz with integrated graphics and memory controllers Direct Media Interface DMI and Flexible Display Interface FDI connectivity to the Intel H61 Express Chipset Dual channel DDR3 1333 1600 MHz memory is supported up to a maximum of 16GB in two DIMM slots These advanced features coupled with dual PCI Express based Gigabit Ethernet SA...

Page 16: ...X Dual Gigabit Ethernet X 8x USB 2 0 ports 2x faceplate 6x onboard pin headers X 4x SATA 3 Gb s ports X 6x COM ports including 1x RS 232 422 485 with auto flow control X Watchdog Timer Hardware Monitor X Optional HD audio kit DB Audio2 daughter board X RoHS compliant NOTE NOTE To purchase the optional DB Audio2 daughter board please contact your ADLINK sales representative ...

Page 17: ...stem reset Hardware Monitor CPU System temperature fan speed and onboard DC voltage by ADLINK Smart Embedded Management Agent SEMA Operating Systems Windows XP Windows 7 32 64 bit Fedora 17 Red Hat Enterprise Linux I O Interfaces Serial ATA 4x SATA 3 Gb s ports onboard I O Ports 2x USB 2 0 port on rear panel 6x via onboard header 6x serial ports via onboard pin header 5x RS 232 1x RS 232 422 485 w...

Page 18: ...ecution Environment PXE Wake On LAN 9KB Jumbo Frames Ports Two RJ 45 Ethernet ports Mechanical and Environment Form Factor Standard full size PICMG 1 0 SBC Dimensions 338 x 122 mm L x W Operating Temp 0ºC to 60ºC Storage Temp 20ºC to 80ºC Relative Humidity 10 to 90 non condensing Safety CE FCC Class A ...

Page 19: ...k VGA BIOS LPC SPI Dual Channel DDR3 1333 1600 Max 16GB Intel I211 AT Dual GbE Intel I211 AT PCI Bus 4x Master Audio 6 COM Pin Header for KB MS Intel Intel H61 H61 PCH PCH PCIe to PCI Bridge DVI D PCI to ISA Bridge ISA Bus LEMT LPT 3rd Gen 3rd Gen Intel Core Intel Core i7 i5 i3 i7 i5 i3 dual quad dual quad core core 32 22nm 32 22nm Super I O ...

Page 20: ...r and PCH Intel Flexible Display Interface carries display traffic from the integrated graphics in the processor to the legacy display connectors in the PCH The PCH supports all other required interfaces including PCI Express SATA 3 Gb s USB 2 0 LPC and SPI Dual Channel DDR3 Memory To meet the requirements of memory intensive applications the NuPRO A40H has a dual channel memory architecture suppo...

Page 21: ...onsumption X SMC Flags A graphical user interface program called SEMAGui and com mand line tool called SEMA Tool are available to allow you to communicate with SEMA Please refer to the SEMA Software and Technical Manuals available for download on the product page Watchdog Timer The watchdog timer WDT monitors system operations based on user defined configurations The WDT can be programmed for dif ...

Page 22: ...8 Introduction 1 6 Mechanical Drawing Figure 1 2 NuPRO A40H Board Dimensions ...

Page 23: ... Y cable w bracket optional P N 30 01052 2000 LAN1 2 RJ 45 Y Act Link Speed LEDs PS 2 KB MS Y cable w bracket optional P N 30 01019 2000 USB Rear Panel 2 USB headers 6 2 54mm pitch COM1 2 Y 2 54mm pitch COM3 6 Y 2 00mm pitch Parallel port Y cable w bracket optional P N 30 25019 1000 SATA 4 PCI 32bit 33MHz Y Via ITE IT8892E ISA Y Via ITE IT8888G ...

Page 24: ... Windows 7 Idle Power Req 12V 5V Total Current A 1 47A 2 77A Power W 17 64W 13 85W 31 49W Windows 7 CPU Stress 100 CPU BurnInTest Stress Power Req 12V 5V Total Current A 5 33A 2 89A Power W 63 96W 14 45W 78 41W Windows 7 Total System Stress 100 BurnInTest Stress Power Req 12V 5V Total Current A 6 92A 3 66A Power W 83 04W 18 3W 101 34W Inrush Current Power Req 12V 5V Total Current A 5 7A 2 69A Powe...

Page 25: ...data cable with latch x2 X 2 port USB cable with bracket X 2 port COM cable with bracket for COM1 COM2 2 54 mm pitch X 2 port COM cable with bracket x2 for COM3 6 2 0 mm pitch X Driver DVD X User s manual NOTE NOTE Package contents may vary with ordering options WARNING The NuPRO A40H must be protected from static discharge and physical shock Never remove any of the socketed parts except at a stat...

Page 26: ...12 Introduction This page intentionally left blank ...

Page 27: ...n assignments and jumper settings 2 1 Rear Panel I O Ports Figure 2 1 Rear Panel I O Ports USB Connector Connector Description 1 LAN1 port Gigabit Ethernet RJ 45 2 LAN2 port Gigabit Ethernet RJ 45 3 VGA port DB 15 connector for CRT or LCD monitor 4 USB 2 0 ports High speed USB 2 0 ports Pin Signal Name 1 Vcc 2 Data 3 Data 4 GND 1 2 3 4 ...

Page 28: ... BI_DB 4 BI_DC 5 BI_DC 6 RX BI_DB 7 BI_DD 8 BI_DD LED1 LED2 Status Description Status Description Off No Link Off 10 Mb connection On Linked Green 100 Mb connection Blinking Data Activity Orange 1 Gb connection Pin Signal Pin Signal 1 Red 9 5 V 2 Green 10 Ground 3 Blue 11 NC 4 NC 12 DDC DAT 5 Ground 13 HSYNC 6 Ground 14 VSYNC 7 Ground 15 DDC CLK 8 Ground LED2 LED1 1 8 ...

Page 29: ...ector 8 CN12 COM3 connector 9 CN19 COM4 connector 10 CN26 COM6 connector 11 CN17 DVI D onboard connector 12 CN10 COM1 connector 13 CN18 COM2 connector 14 15 CN8 6 USB 8 9 4 5 headers 16 CN16 PS 2 Keyboard Mouse pin header 17 CN3 USB 2 3 header 18 CN9 Audio connector 19 CN7 SATA5 connector 20 CN9 SATA4 connector 21 CN2 SATA0 connector 22 CN4 SATA1 connector 23 CN28 Clear CMOS jumper 24 CN29 Clear R...

Page 30: ...nnector 2 54mm pitch Pin Signal 1 GND 2 GND 3 12V DC 4 12V DC NOTE NOTE The ATX 12V power connector must be connected to provide sufficient power to the SBC in either ATX or AT modes See Installing the Power Connectors on page 36 Pin Signal 1 GND 2 Fan power 12V 3 Fan Tachometer 4 Fan Speed Control 1 3 2 4 1 4 ...

Page 31: ...NC 3 HC_PLED L Power LED signal 4 NC 5 GND Ground 6 GND Ground ATX Power 7 NC 8 ATX_PSON L ATX Power On signal 9 P5V_SB_ATX 5V Standby 10 PMEJ Power Control signal 11 HC_SPKR Speaker signal Chassis Speaker 12 NC 13 NC 14 P5V 5V Power 15 HC_RSTBN L Reset signal Reset Button 16 GND Ground 17 HDLED_PWR HDD LED signal HDD LED 18 P5V 5V Power 19 HC_PBTNJ Power On signal Power Button 20 GND Ground 1 10 ...

Page 32: ...a 4 12 Ground 13 Parallel Data 5 14 Ground 15 Parallel Data 6 16 Ground 17 Parallel Data 7 18 Ground 19 Acknowledge 20 Ground 21 Busy 22 Ground 23 Paper Empty 24 Ground 25 Select 26 NC Pin Signal Pin Signal 1 Line Printer Strobe 14 Auto Feed 2 Parallel Data 0 15 Error 3 Parallel Data 1 16 Initialize 4 Parallel Data 2 17 Select 5 Parallel Data 3 18 Ground 6 Parallel Data 4 19 Ground 7 Parallel Data...

Page 33: ...VI I2C Data 12 DVI Data1 13 GND 14 GND 15 DVI HPD 16 DVI Data2 17 5V 18 DVI Data2 19 GND 20 GND Pin Signal Pin Signal 1 TMDS Data2 13 TMDS Data3 2 TMDS Data2 14 5 V Power 3 TMDS Data2 4 Shield 15 GND 4 TMDS Data4 16 Hot Plug Detect 5 TMDS Data4 17 TMDS Data0 6 DDC Clock SCL 18 TMDSData0 7 DDC Data SDA 19 TMDS Data0 5 Shield 8 Analog vertical sync 20 TMDS Data5 9 TMDS Data1 21 TMDS Data5 10 TMDS Da...

Page 34: ...32 422 485 mode COM2 3 4 5 6 Connectors RS 232 CN12 18 19 25 26 2x5 box header 2 00mm pitch Pin RS 232 RS 422 485 RS 485 1 DCD TXD Data 2 DSR NC NC 3 RXD TXD Data 4 RTS NC NC 5 TXD RXD NC 6 CTS NC NC 7 DTR RXD NC 8 RI NC NC 9 GND GND GND 10 NC NC NC Pin RS 232 Signal 1 DCD 2 DSR 3 RXD 4 RTS 5 TXD 6 CTS 7 DTR 8 RI 9 GND 10 NC 1 2 9 10 1 2 9 10 ...

Page 35: ...h the NuPRO A40H DB9 connector USB 2 0 Connectors CN3 6 8 2x5 box header 2 54mm pitch Pin RS 232 RS422 485 RS485 1 DCD TXD Data 2 RXD TXD Data 3 TXD RXD 4 DTR RXD 5 GND GND GND 6 DSR 7 RTS 8 CTS 9 RI Pin Signal Pin Signal 1 5V 2 5V 3 USB0 4 USB1 5 USB0 6 USB1 7 GND 8 GND 9 Key 10 NC 1 5 6 ...

Page 36: ...019 2000 PS 2 Mouse Port green PS 2 Keyboard Port purple Pin Signal Pin Signal 1 KBDATA 2 KBCLK 3 MSDATA 4 MSCLK 5 KM_VCC 6 GND Pin Signal Function 1 MSDATA Mouse Data 2 NC not connected 3 GND Ground 4 5V Power 5 CLK Clock 6 NC not connected Pin Signal Function 1 KBDATA Keyboard Data 2 NC not connected 3 GND Ground 4 5V Power 5 CLK Clock 6 NC not connected 1 2 ...

Page 37: ...ughter board Serial ATA Connectors CN2 4 7 9 7P L connector 1 27mm pitch Pin Signal Function 1 GND Ground 2 AUD_BCLK Audio Clock 3 GND Ground 4 ICH_AUD_SDIN1 Audio Data Input 5 P5V 5V 6 ICH_AUD_SDOUT Audio Data Output 7 P5V_AUD 5V 8 P3V3_DVDD 3 3V 9 AUD_SYNC Audio Synchronous 10 AUD_RSTJ Audio Reset Pin Signal 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND 1 2 9 10 1 7 ...

Page 38: ...CRTS asserts 1 Power down and disconnect power from the system 2 Short pins 2 3 on JP1 3 Reconnect power and power up the system 4 After power up remove the jumper cap from pins 2 3 and reinstall it to pins 1 2 WDT Status Connection Normal default 1 2 Disabled 2 3 CMOS Status Connection JBAT1 Normal 1 2 Clear CMOS 2 3 ...

Page 39: ...Short pins 2 3 on JP1 3 Reconnect power and power up the system After power up remove the jumper cap from pins 2 3 and reinstall it to pins 1 2 COM1 Mode Jumper Settings CN16 CN31 Short the jumper pins according to the following settings to set COM1 to RS 232 422 485 mode CMOS Status Connection JBAT1 Normal 1 2 Clear CMOS 2 3 RS 232 RS 422 RS 485 CN16 On On Off CN31 Off On On ...

Page 40: ...26 Hardware Information This page intentionally left blank ...

Page 41: ...or in an LGA1155 socket To install the CPU 1 Press down on the locking arm A then push it away from the socket to disengage it from the retention tab B WARNING Disconnect all power to the board before installing a CPU to prevent damaging the board and CPU Do not touch socket contacts Damaging the contacts voids the product warranty Follow the installation instructions carefully to avoid damaging t...

Page 42: ...ing arm to unlock the load plate 3 Lift the load plate to uncover the socket 4 Remove the plastic protective cover from the socket Note the locations of the alignment keys A and Pin 1 indicator B WARNING Do NOT touch socket contacts A B ...

Page 43: ...ment keys on the socket A The golden triangle on the CPU must be positioned at the corner of the socket with the Pin 1 indi cator as shown B 6 Carefully place the CPU into the socket vertically The socket has cutouts for your fingers to fit into WARNING The CPU fits into the socket in only one orientation DO NOT force it into the socket to avoid causing damage A B Cutouts ...

Page 44: ...ntly lower the load plate Make sure the front edge of the plate is under the screw as indicated 8 Lower the locking arm and fasten it to the retention tab A The load plate should be locked underneath the screw as shown B A B ...

Page 45: ... on top of the installed CPU 2 Lower the CPU fan to the CPU then secure it using the provided attachments or screws 3 Connect the CPU fan cable to the CPU fan connector on the SHB labeled FAN1 see Board Layout on page 15 CAUTION The CPU requires a chassis with an airflow inlet and maximum internal ambient temperature of 50 C A especially designed CPU fan and heatsink must be installed before using...

Page 46: ...IMMs in the following configurations X Channel A DIMM1 Channel B DIMM2 X For dual channel configuration the total size of memory module installed per channel must be the same DIMM1 DIMM2 X It is recommended that you install DIMMs with the same CAS latency For maximum compatibility install memory modules with the same brand model and or rating To install a memory module 1 Locate the DIMM sockets on...

Page 47: ... 3 Align the memory module on the socket making sure that the notch matches the break on the socket 4 Insert the module firmly into the slot until the retaining clips snap back inwards and the module is securely seated Break Notch ...

Page 48: ...V DC power connected to CN24 for proper operation in either ATX or AT modes If necessary order an ATX12V Convert Cable from ADLINK for use with Molex 4 pin power connectors P N 30 00006 0000 Front Panel Connector Before powering up the NuPRO A40H connect the necessary sig nals from the backplane to the System Panel pin header CN23 The ATX Power Connector pin group pins 6 8 9 10 and Power Button pi...

Page 49: ...e DVD and extract the file setup exe from the following archive Chipset driver_ Intel_INF_Update_Utility_All_WinOS zip 2 Run the program setup exe and follow the onscreen instructions Restart the system if prompted 4 2 Display Driver Integrated Intel HD Graphics This section describes the driver installation for the Integrated Intel HD Graphics Follow these instructions to install the display driv...

Page 50: ... file Autorun exe from the following archive Network_driver_Intel_Network_Adapter_For_Win32 zip 2 Run the program Autorun exe and follow the onscreen instructions Restart the system if prompted 4 4 Audio Driver Follow these instructions to install the audio driver for the optional DB Audio2 daughter board 1 Place the ADLINK All in One DVD to the optical drive 2 Locate the audio driver from the dir...

Page 51: ...erboard 2 Press the Delete key on your keyboard when you see the following text prompt Press DEL to run Setup 3 After you press the Delete key the main BIOS setup menu displays You can access the other setup screens from the main BIOS setup menu such as Chipset and Power menus Note In most cases the Delete key is used to invoke the setup screen There are several cases that use other keys such as F...

Page 52: ...annot be configured Blue options can be The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will accompany it Navigation The BIOS setup utility uses a key based navigation system called hot keys Most of the BIOS setup utility hot keys can be used at any time ...

Page 53: ...set the Fail Safe settings of the BIOS press the F8 key on your keyboard It is located on the upper row of a standard 101 keyboard The Fail Safe set tings allow the motherboard to boot up with the least amount of options set This can lessen the probability of conflicting settings Hotkey Descriptions F1 The F1 key allows you to display the General Help screen Press the F1 key to open the General He...

Page 54: ...us screen ESC The Esc key allows you to discard any changes you have made and exit the Setup Press the Esc key to exit the setup without saving your changes The following screen will appear Press the Enter key to discard changes and exit You can also use the Arrow key to select Cancel and then press the Enter key to abort this function and return to the pre vious screen Enter The Enter key allows ...

Page 55: ...ing the Main tab There are two Main Setup options They are described in this section The Main BIOS Setup screen is shown below System Board Info BIOS Vendor Displays the BIOS vendor Core Version Displays the BIOS core version BIOS Version Display the current BIOS revision Build Data and Time Displays the BIOS build data Total Memory Display the current system total memory ...

Page 56: ...ow keys Enter new val ues using the keyboard Press the Tab key or the Arrow keys to move between fields The date must be entered in MM DD YY format The time is entered in HH MM SS format Note The time is in 24 hour format For example 5 30 A M ap pears as 05 30 00 and 5 30 P M as 17 30 00 Access Level Displays the current system access level ...

Page 57: ...etup screen You can select any of the items in the left frame of the screen such as SuperIO Configuration to go to the sub menu for that item You can display an Advanced BIOS Setup option by highlighting it using the Arrow keys The Advanced BIOS Setup screen is shown below The sub menus are described on the following pages ...

Page 58: ...abled ACPI Sleep State Select the highest ACPI sleep state the system will enter when the SUSPEND button is pressed Options S1 S3 Suspend Disable AC Power Shutdown ATX mode OS will turn off system power when shutdown AT mode OS show It is now safe to turn off your computer NOTE NOTE AT mode will not support S3 S4 ...

Page 59: ...ven if the processor sup ports a higher CPUID input value When Disabled the proces sor will return the actual maximum CPUID input value of the processor when queried Enable this option to allow compatibil ity with older operating systems Execute Disable Bit Allows you to enable or disable the No Execution Page Protec tion Technology Setting this item to Disabled forces the XD feature flag to alway...

Page 60: ...Tech When enabled Intel Virtualization Technology Intel VT makes a single system appear as multiple independent sys tems to software This allows for multiple independent operat ing systems to be running simultaneously on a single system ...

Page 61: ...BIOS Setup 47 NuPRO A40H 5 3 3 SATA Configuration SATA Mode Options IDE RAID AHCI IDE Legacy Native Mode Selection IDE Legacy Native Mode Selection SATA Port 0 1 4 5 Display SATA device name string ...

Page 62: ...hen this option is enabled any attached USB mouse or USB keyboard can control the system even when there are no USB drivers loaded on the system Set this value to enable or disable the Legacy USB Support X Disabled Set this value to prevent the use of any USB device in DOS or during system boot X Enabled Set this value to allow the use of USB devices during boot and while using DOS X Auto This opt...

Page 63: ...ll take before it properly reports itself to the Host Controller Auto uses default value for a Root port it is 100ms for a Hub port the delay is taken from Hub descriptor Mass Storage Devices Mass storage device emulation type AUTO enumerates devices according to their media format Optical drives are emulated as CDROM drives with no media will be emulated according to a drive type Options Auto Flo...

Page 64: ...Serial Port 1 6 Configuration Enter the submenu for each serial port to enable disable and view the I O port and IRQ settings Parallel Port Configuration Enter the submenu to enable disable the parallel port and specify the base I O port address ...

Page 65: ...BIOS Setup 51 NuPRO A40H 5 3 6 Serial Port Console Redirection COM1 6 Console Redirection Options Enabled Disabled ...

Page 66: ... the serial port to use for console redirection The options are 115200 57600 38400 19200 9600 Data Bits Select the data bits you want the serial port to use for console redirection Set this value to 7 and 8 Parity Set this option to select Parity for console redirection The set tings for this value are None Even Odd Mark and Space Stop Bits Stop bits indicate the end of a serial data packet A star...

Page 67: ...Resolution On a legacy OS the number of Rows and Columns supported by redirection Set this value to 80x24 and 80x25 Serial Port for Out of Band Management These settings control the ACPI serial port redirection table SPCR which is used by Windows servers to provide Windows Emergency Management Services EMS and is independent from console redirection output OoB Management or EMS allows the remote m...

Page 68: ...I Bits per second Select the bits per second you want the serial port to use for console redirection The options are 115200 57600 38400 19200 9600 Flow Control Set this option to select Flow Control for console redirection The settings for this value are None Hardware RTS CTS Data Bits Displays the frame width for Out of Band Management Parity Displays the parity for Out of Band Management Stop Bi...

Page 69: ... this value to Enabled Disabled Turbo Mode Enabled Disabled CPU Turbo Mode in OS CPU C3 Report CPU C3 ACPI C2 report to OS Set this value is Enabled Dis abled CPU C6 Report CPU C6 ACPI C3 report to OS Set this value is Enabled Dis abled CPU C7 Report CPU C7 ACPI C3 report to OS Set this value is Enabled Dis abled ...

Page 70: ...p Select the Chipset tab from the setup screen to enter the Chipset BIOS Setup screen You can select any of the items in the left frame of the screen to go to the sub menu for that item The Chip set BIOS Setup screen is shown below ...

Page 71: ...BIOS Setup 57 NuPRO A40H 5 4 1 PCH IO Configuration High Precision Timer Enabled Disabled the High Precision Event Timer Slp_S4 Assertion Width Select a minimum assertion width of the SLP_S4 signal ...

Page 72: ...to always power off the system while AC power is restored X Power On Set this value to always power on the system while AC power is restored X Last State Set this value to power off on the system depend ing on the last system power state while AC power is restored USB Configuration EHCI 1 Enabled Disabled USB 2 0 EHCI Support Options Enable Dis able EHCI 2 Enabled Disabled USB 2 0 EHCI Support Opt...

Page 73: ...zaila will be unconditionally disabled X Enabled Azaila will be unconditionally Enabled X Auto Azalia will be enabled if present disabled otherwise Azalia Docking Support Enabled Disabled Azalia Docking Support of Audio Controller Azalia PME Enabled Disabled Power Management Capability of Audio Con troller ...

Page 74: ...60 BIOS Setup 5 4 2 System Agent SA Configuration Graphics Configuration Graphic Turbo IMON Current Graphic Turbo IMON Current values supported 14 31 μA ...

Page 75: ...TT Graphics Memory Manager size Options 1MB 2MB Aperture Size Options 128MB 256MB 512MB DVMT Pre Allocated Select DVMT 5 0 Pre allocated Fixed Graphics Memory size used by the Internal Graphics Device DVMT Total Gfx Mem Select DVMT Fixed memory size used by the Integrated Graphics Device Options 128MB 256MB Maximum Gfx Low Power Mode Options Enabled Disabled Graphics Performance Analyzers Enabled ...

Page 76: ...62 BIOS Setup Memory Configuration Memory Remap Enabled or Disable Memory remap above 4G ...

Page 77: ... as Boot Device Priority to go to the sub menu for that item You can display a Boot BIOS setup option by highlight ing it using the Arrow keys The Boot Configuration screen is shown below Setup Prompt Timeout Number of seconds to wait for setup activation 65535 0xFFFF means wait indefinitely Bootup NumLock State This setting determines the state of the NumLock function on bootup Options On Off ...

Page 78: ...Trap Response BIOS reaction on INT19 trapping by Option ROM IMMEDI ATE execute the trap right away POSTPONED execute the during legacy boot Boot Option Priorities Set the boot device options to determine the sequence in which the computer checks which device to boot from Hard Drive BBS Priorities The Boot devices are listed in groups by device type First press Enter to enter the sub menu You may t...

Page 79: ...oot to Launch PXE OpRom Policy Controls the execution of UEFI and Legacy PXE OpRom Launch Storage OpRom Policy Controls the execution of UEFI and Legacy Storage OpRom Launch Video OpRom Policy Controls the execution of UEFI and Legacy Video OpRom Other PCI device ROM priority For PCI device other than network mass storage or Video defines which OpRom to launch ...

Page 80: ...word every time the system boots or when Setup is exe cuted using either or either the Supervisor password or User password The Supervisor and User passwords activate two different lev els of password security If you select password support you are prompted for a one to six character password Type the password on the keyboard The password does not appear on the screen when typed Make sure you writ...

Page 81: ...erase the sys tem configuration information in NVRAM To access the sub menu for the following items select the item and press Enter X Change Administrator Password X Change User Password X Clear User Password Administrator Password Indicates whether a Administrator password has been set User Password Indicates whether a user password has been set ...

Page 82: ...68 BIOS Setup 5 7 System Management Power Up Watchdog The Power Up Watchdog resets the system after a certain amount of time after power up ...

Page 83: ...ting it using the Arrow keys The Exit BIOS Setup screen is shown below Save Changes and Exit When you have completed the system configuration changes select this option to leave Setup and reboot the computer so the new system configuration parameters can take effect Save Configuration Changes and Exit Now Ok Cancel appears in the window Select Ok to save changes and exit ...

Page 84: ...es made so far to any of the setup options Discard Changes Select Discard Changes from the Exit menu and press Enter Select OK to discard changes Restore Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes made so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override This group of functions incl...

Page 85: ... the fol lowing location C Windows System32 drivers A sample program for configuring the NuPRO A40H s watchdog timer is shown below A 1 Sample Code include stdlib h include float h include Sema h include SemaLog h include ErrorCodes h include Debug h include Conv h include dmi_info h include Version h ifdef WIN32 include windows h else include string h include unistd h include ctype h endif typede...

Page 86: ...strncmp argv i wdt 3 0 if i argc ErrorMessage Watchdog Timeout missing Args Watchdog atoi argv i Args SetWatchdog true void PrintData tCmdLineArgs Args if Args SetWatchdog Sema_SetWatchdog Args Watchdog printf Watchdog set to d seconds n Args Watchdog int main int argc char argv memset CmdLineArgs 0 sizeof tCmdLineArgs ParseArgs argc argv CmdLineArgs Sema_Init ...

Page 87: ...Watchdog Timer 73 NuPRO A40H PrintData CmdLineArgs Print requested data to console Sema_Close return 0 ...

Page 88: ...74 Watchdog Timer This page intentionally left blank ...

Page 89: ...MB 4GB 19MB 1 FEC00000 FECFFFFF 1 MB APIC Configuration Space 15MB 16MB F00000 FFFFFF 1 MB ISA Hole 960 K 1024 K F0000 FFFFF 64 KB System BIOS Area 896 K 960 K E0000 EFFFF 64 KB Extended System BIOS Area 768 K 896 K C0000 DFFFF 128 KB PCI expansion ROM area C0000 CE7FF Onboard VGA BIOS CE800 D07FF Intel i211 PXE option ROM when onboard LAN boot ROM is enabled 640 K 768 K A0000 BFFFF 128 KB Video B...

Page 90: ...nterrupt controller 2 8259 equivalent 0B2 and 0B3 APM control and status port respectively 0C0 0DF DMA controller 2 8237A 5 equivalent 0F0 Co processor error register 2E0 2EF Serial Port 6 2E8 2EF Serial Port 4 2F0 2F7 Serial Port 5 2F8 2FF Serial Port 2 378 37F Parallel port 3B0 3BB and 3BF Mono VGA mode video 3BC 3BE Reserved for parallel port 3C0 3DF VGA registers 3E8 3FF Serial port 3 3F8 3FF ...

Page 91: ...A No 3 Serial Port 2 COM2 IRQ3 via SERIRQ IRQ3 at ISA bus Note 1 4 Serial Port 1 COM1 PCI ISA IRQ4 via SERIRQ IRQ4 at ISA bus Note 1 5 Serial Port 3 4 COM3 COM4 PCI ISA IRQ5 via SERIRQ IRQ5 at ISA bus Note 1 6 Serial Port 5 COM5 PCI ISA IRQ6 via SERIRQ No 7 Parallel port PCI ISA IRQ7 via SERIRQ IRQ7 at ISA bus Note 1 8 Real time clock N A No 9 SCI PCI IRQ9 via SERIRQ IRQ9 at ISA bus Note 1 2 10 Se...

Page 92: ...ISA IRQ15 via SERIRQ IRQ15 at ISA bus Note 1 IRQ Typical Interrupt Resource Connected to Pin Available 0 Counter 0 N A No 1 Keyboard controller N A No 2 Cascade interrupt from slave PIC N A No 3 Serial Port 2 COM2 ISA IRQ3 via SERIRQ IRQ3 at ISA bus Note 1 4 Serial Port 1 COM1 ISA IRQ4 via SERIRQ IRQ4 at ISA bus Note 1 5 Serial Port 3 4 COM3 COM4 ISA IRQ5 via SERIRQ IRQ5 at ISA bus Note 1 6 Serial...

Page 93: ...A IRQ12 via SERIRQ IRQ12 at ISA bus Note 1 13 Math Processor N A No 14 Primary IDE controller ISA IRQ14 via SERIRQ IRQ14 at ISA bus Note 1 15 Secondary IDE controller ISA IRQ15 via SERIRQ IRQ15 at ISA bus Note 1 16 N A PCIE Port 0 EHCI Controller 2 I G D Intel Management Engine Interface PCIE to PCI Bridge IT8892 PCI SLOT1 Yes 17 N A PCI SLOT4 Yes 18 N A PCIE Port 2 Intel I211 LAN PCI SLOT3 Yes 19...

Page 94: ...0h 1Ch 02h Internal Intel ICH Express Root port 2 00h 1Ch 03h Internal Intel ICH Express Root port 3 00h 1Dh 00h Internal Intel USB EHCI Controller 1 00h 1Fh 00h N A Intel LPC Interface Bridge 00h 1Fh 02h Internal Intel SATA Host controller 1 00h 1Fh 03h Internal Intel SMBus Controller 00h 1Fh 05h Internal Intel Host SATA controller 2 01h 00h 00h Internal IT8892 PCIE to PCI Bridge 02h 07h 00h Inte...

Page 95: ... A B C D E F G H INT Line INTA INTB INTC INTD VGA X SATA Controller X SATA Controller 1 X EHCI 1 X EHCI 2 X HAD X PCIE port0 INTA INTB INTC INTD PCIE port2 INTC INTD INTA INTB PCIE port3 INTD INTA INTB INTC IT 8892 X PCI Slot 1 X PCI Slot 2 X PCI Slot 3 X PCI Slot 4 X Intel I211 1 X Intel I211 2 X ...

Page 96: ...82 System Resources This page intentionally left blank ...

Page 97: ... Turn off power and unplug any power cords cables X To avoid electrical shock and or damage to equipment Z Keep equipment away from water or liquid sources Z Keep equipment away from high heat or high humidity Z Keep equipment properly ventilated do not block or cover ventilation openings Z Make sure to use recommended voltage and power source settings Z Always install and operate equipment near a...

Page 98: ...viced by authorized technicians when Z The power cord or plug is damaged Z Liquid has penetrated the equipment Z It has been exposed to high humidity moisture Z It is not functioning or does not function according to the user s manual Z It has been dropped and or damaged and or Z It has an obvious sign of breakage WARNING Risk of explosion if battery is replaced with one of an incorrect type Dispo...

Page 99: ...ang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology Beijing Address ҀᏖ ऎϞഄϰ䏃 1 োⲜ ࡼ ॺ E ᑻ 801 ᅸ 100085 Rm 801 Power Creative E No 1 B D Shang Di East Rd Beijing 100085 China Tel 86 10 5885 8666 Fax 86 10 5885 8626 Email market adlinktech com ADLINK Technology Shenzhen Address ഇᏖफቅऎ ᡔುफऎ催ᮄफϗ䘧...

Page 100: ...r B D 1675 12 Seocho Dong Seocho Gu Seoul 137 070 Korea Tel 82 2 2057 0565 Fax 82 2 2057 0563 Email korea adlinktech com ADLINK Technology Singapore Pte Ltd Address 84 Genting Lane 07 02A Cityneon Design Centre Singapore 349584 Tel 65 6844 2261 Fax 65 6844 2263 Email singapore adlinktech com ADLINK Technology Singapore Pte Ltd Indian Liaison Office Address 1st Floor 50 56 Between 16th 17th Cross M...

Reviews: