MR-J2S-B Alarm List
When any alarm has occurred, eliminate its cause, ensure safety,
then deactivate the alarm, and restart operation. Not doing so can
cause injury.
AL.10 Undervoltage
Power supply voltage dropped.
MR-J2S-B: 160V or lessMR-J2S-
oB1: 83V or less
AL.12
Memory alarm 1
RAM memory fault
AL.13
Clock alarm
Printed board fault
AL.15
Memory alarm 2
EEPROM fault
AL.16 Encoder
alarm
1
Communication error occurred
between encoder and servo ampli-
fier.
AL.17 Board
alarm
CPU/parts
fault
AL.19
Memory alarm 3
ROM memory fault
AL.1A
Motor combination
alarm
Combination of servo amplifier and
servo motor is wrong.
AL.20 Encoder
alarm
2
Communication error occurred
between encoder and servo ampli-
fier.
AL.24 Main
circuit
error
Ground fault occurred at the servo
motor outputs (U, V, W phases) of
the servo amplifier.
AL.25 Absolute position erase
Absolute position data in error-
Power was switched on for the first
time in the absolute position detec-
tion system.
AL.30 Regenerative
alarm
The permissible regenerative
power of the built-in regenerative
brake resistor or regenerative
brake option is exceeded.Regener-
ative transistor fault
AL.31 Overspeed
Speed has exceeded the instanta-
neous permissible speed.
Table 6-1: MR-J2S-B Alarm List
Summary of Contents for PCI-8366+
Page 4: ......
Page 14: ...x List of Figures ...
Page 17: ...Introduction 3 Figure 1 3 Flowchart for Building an Application ...
Page 26: ...12 Installation 2 2 PCI 8372 8366 Outline Drawing Figure 2 1 PCI 8372 8366 Mechanical Drawing ...
Page 31: ...Installation 17 2 Press HPI boot ...
Page 32: ...18 Installation 3 Press Flash DL button and select a kernel4 hex ...
Page 34: ...20 Installation Figure 2 3 SSCNET Communication Test Utility ...
Page 49: ...Signal Connections 35 Figure 3 9 Skin Type ...
Page 144: ...130 Operation Theory ...
Page 149: ...Motion Creator 135 Figure 5 6 Software Version Information ...
Page 160: ...146 Motion Creator Figure 5 13 Channel Selection Frame Figure 5 14 Motion Frame ...