8
Specifications
Leading
EDGE COMPUTING
Environmental (cont’d)
EMS
IEC 61000-4-2 (ESD, contact: ±8kV, air: ±15kV)
IEC 61000-4-3 (RS, 10V/m from 80-1000MHz, 3V/m from 1400-
2000MHz, 1V/m from 2000-2700MHz, 1kHZ sine wave, 80% AM)
IEC 61000-4-4 (EFT, ±2kV at 5KHz on power port, ±1kV at 5KHz
on signal port)
IEC 61000-4-5 (Surge, ±2kV line to earth CM on power port,
±1kV line to earth CM on signal port)
IEC 61000-4-6 (CS, 10Vrms with 1kHz sine wave, 80% AM from
0.15MHz-80MHz)
IEC 61000-4-8 (power-frequency magnetic fields)
IEC 61000-4-11 (voltage DIPs & voltage interruptions)
EMI
CE & FCC Class B with validated AC/DC adapter
(EN61000-6-4/-2)
Safety
UL/cUL, CB
RQI-55(-E)
RQI-53(-E)
Summary of Contents for ROScube-I Series
Page 8: ...viii List of Tables Leading EDGE COMPUTING This page intentionally left blank ...
Page 10: ...x List of Figures Leading EDGE COMPUTING This page intentionally left blank ...
Page 24: ...14 Specifications Leading EDGE COMPUTING This page intentionally left blank ...
Page 42: ...32 System Layout Leading EDGE COMPUTING This page intentionally left blank ...
Page 46: ...36 Getting Started Leading EDGE COMPUTING This page intentionally left blank ...
Page 52: ...42 BIOS Setup Leading EDGE COMPUTING B 2 1 CPU Configuration ...
Page 94: ...84 Consignes de Sécurité Importante Leading EDGE COMPUTING This page intentionally left blank ...