4-3
LUBRICANT SYSTEM
•
Take-off the fixed bolts on oil pump
and remove the oil pump ass’y.
Disassembling:
•
Take-off the screw on oil pump and
disassembling the oil pump.
Check:
•
Check the gap between the pump
body and outer rotor.
The gap limit is 0.10 mm.
•
Check the gap between inner and
outer
rotor.
The gap limit is 0.06 mm.
bolt