INSTALLATION
IMPORTANT NOTE:
The cleaners power supply is also equipped with a Residual-Current Device (RCD). This device disconnects the power circuit whenever it detects
that there is not a balance between the power and the return neutral conductor. Such an imbalance is sometimes caused by current leakage
through the body of a person who is grounded and accidentally touching the powered part of the circuit and will prevent injury caused by such
shocks. They are not intended to provide protection against overload or short circuit conditions, the earth leakage circuit breaker below will
handle this situation.
WARNING:
It is strongly recommended that you test the RCD prior to using the cleaner power supply.
RCD OPERATION:
1. Plug power supply lead into dedicated electrical outlet.
2. Press RESET button and the indicator light should be on “Lite”.
3. Press TEST button and the indicator light should be on “Off”.
4. Press RESET button for use of the cleaner, do not use if TEST fails and indicator is on “Lite”.
■
This RCD is not an overload protection device.
■
This RCD device complies SAA AS/NZS3190, Approval No A/10643EA.
■
Do not plug the power supply lead into an extension cord.
WARNING:
1. DO NOT RUN THE CLEANER OUT OF THE WATER. OPERATING THE CLEANER OUT OF THE WATER WILL DAMAGE THE MOTORS AND VOID THE WARRANTY
2. THE Admiral ATV-NAV SHOULD NOT BE CONNECTED TO A TIMING DEVICE AND LEFT CONTINUOUSLY WITHIN A POOL OR SPA.
3. ENSURE ALL CONNECTIONS TO THE SWIVEL ARE SECURE PRIOR TO PLACING THE CLEANER IN THE POOL.
6
■
Ensure power supply (transformer) is in the off position.
■
Plug the power transformer lead into its own dedicated 220-240V, 50Hz AC
electrical outlet.
It is essential the power point is properly connected to an earth leakage circuit
breaker and properly earthed to ground. Consult a qualified electrician if you
are unsure.
■
Do not plug the power supply lead into an extension cord.
■
Plug the floating blue power cord into the power transformer 25V connection socket.
■
Attach the antenna to the power supply by aligning the base of the antenna with the gold connector on the power supply. Twist the antenna
onto the connector in a clockwise direction until snug. DO NOT OVERTIGHTEN.
■
Plug in the connector of the blue power cord from the cleaner into the power supply
(transformer). The connector is keyed so that it will only plug into the power supply
(transformer) one way. Make sure that the plug is pushed all the way onto the power
supply (transformer). Slide the connector lock (strain relief) onto the connector and
turn the connector lock clockwise until it is tight (Do not over tighten).