background image

CHIMNEY INSTALLATION 

(CONTINUED)

15)  STRAIGHT  CHIMNEY  SECTIONS 

–  Before  running 

the  straight  chimney  through  the  roof,  slide  the 
Firestop  Spacer  (shown  in  FIG.  16)  over  the  Return 
Elbow.  Now,  snap  the  remaining  Straight  Chimney 
sections into place.  

  If the chimney is 30’ or higher, a support section (a 

4‐strap  x  12”  length  of  pipe)  is  required  after  a 
straight chimney section above the fireplace run, or 
above a Return Elbow. The support section will sup‐
port the increased weight of the chimney. 

FIG. 15 ‐ 

STRAIGHT CHIMNEY 

15 

MODEL 

A  

KIVA18 & KIVA 24 

KIVA30  

GAS ONLY 

17 

1

/

2

” 

WOOD OR GAS 

20 

1

/

2

” 

17 

1

/

2

” 

2” MIN. AIR 

SPACE TO 

COMBUSTIBLES! 

 

FIG. 15.1 ‐ 

10’ RULE 

10‐FOOT RULE 

All  chimney  terminations  must  extend  at  least  3’ 

above the highest point where it passes through the 
roof  and  must  be  2’  above  the  peak  of  the  roof  or 
any other building structure within a horizontal dis‐
tance of 10’.  

 

16 

FIG. 16 ‐ 

FIRESTOP SPACERS 

 

16)  FIRESTOP  SPACERS 

–  Firestop  Spacers  are  required  at 

each point where the chimney penetrates a floor or ceil‐
ing joist space. Attach Firestop Spacer to joist using wood 
screws.  

  If the chimney pipe passes through a framed opening into 

an  attic  space,  the  Firestop  must  be  placed  in  the  attic 
floor.  When  the  pipe  passes  through  a  framed  opening 
into living space above, the Firestop must be placed onto 
the ceiling from below. 

  Refer  to  local  building  codes  and  restrictions  for  varia‐

tions in Firestop spacer requirements. 

17) CHIMNEY ROOF FLASHING 

– A flat Chimney Roof Flash‐

ing is used for flat roofs and chimney chases. For pitched 
roofs  a  pitched  flashing  is  used.  Slide  the  Chimney  Roof 
Flashing  down  over  the  last  section  of  straight  chimney 
penetrating the roof or chase and attach to roof. 

  

17 

FIG. 17 ‐ 

CHIMNEY ROOF FLASHING 

 

IMPORTANT: 

If an exposed portion of chimney is greater than 5’ 

above the roof line, use support wires to keep chimney secure. 
The  support  wires  may  be  attached  to  the  outer  pipe  of  the 
chimney with screws but must not penetrate the inner flue pipe.

WARNING: 

DO NOT SEAL VENTILATION OPENINGS ON THE ROOF 

FLASHING!

 

16 

Summary of Contents for KIVA 18 Ornito

Page 1: ...lar steel and diamond mesh frame The frame is finished with stucco after installation C AIR COOLED CHIMNEY Lightweight stainless steel double walled air cooled chimney is used for venting the fireplac...

Page 2: ...2 This page intentionally left blank...

Page 3: ...Manual Combustion Air Intake of fireplace must be kept clear of debris at all times This fireplace is to be installed ONLY by a construction industry licensed contractor Any permits and construction i...

Page 4: ...4 This page intentionally left blank...

Page 5: ...Fireplace Layout 10 11 Fireplace Pedestal 11 2 Firebox Installation 12 Firebox Assembly 12 Door Frame 13 Anchor Plate 13 3 Chimney Installation 14 Installing the Chimney Pipe 14 17 Outside Air Kit In...

Page 6: ...___________ Dealership Purchased at ______________________________________ Dealership Phone __________________________________________ Date Purchased ________________ Date Installed __________________...

Page 7: ...TO COMBUSTIBLES SIDES BACK 1 FACE All framing along firebox face must be non combustible HEARTH EXTENTION 18 CHIMNEY 2 KIVA24 FIREBOX DIMENSIONS TOP VIEW A B C D E F G H I KIVA 24 25 1 4 34 25 44 52 2...

Page 8: ...00 WARNING B Vent Chimney should never be used when solid fuels are to be burned TABLE 1 chimney requirements KIVA30 FIREBOX DIMENSIONS TOP VIEW A B C D E F G H I KIVA 30 30 40 27 1 4 48 1 2 56 1 2 28...

Page 9: ...ural Gas and 39 700 for Liquid Propane STUB OUT Before the Adobelite firebox is installed gas lines should be run into the area where the fireplace will be in stalled A Keyed Gas Shutoff Valve is requ...

Page 10: ...an Electrical Box and Wall Switch or remote control receiver for fireplace control in the wall at the desired location Refer to FIG 1 on page 9 to locate the minimum distance from the corner that the...

Page 11: ...shown in FIG 6 or any other combination of concrete blocks can also be used as long as the overall height is 12 1 Two columns of CMU s should be positioned with the front edge of the blocks against th...

Page 12: ...eces will meet and align the back and sides of the pieces 5 FRONT ARCH Apply refractory mortar to the front edges of the Lower and Upper Back pieces and to the top of the Front Arch sec tion Place the...

Page 13: ...refractory mortar to the top of firebox where the Anchor Plate will sit Align the back edge of the Anchor Plate opening with opening in the firebox top section Secure the Anchor Plate using four dia x...

Page 14: ...The Starter Collar is used to support the outer chimney section while the Anchor Plate collar supports the inner chimney Attach the legs of the Starter Collar to the Anchor Plate with the supplied 12...

Page 15: ...ensions A and E in Layout charts Pages 10 11 Firmly push both the in ner and outer pipes into the Starter Elbow until they snap lock into place 14 RETURN ELBOW Position the Return Elbow so that the ch...

Page 16: ...Firestop Spacers are required at each point where the chimney penetrates a floor or ceil ing joist space Attach Firestop Spacer to joist using wood screws If the chimney pipe passes through a framed o...

Page 17: ...tion air to the firebox therefore not using air from the interior of the house as well as cooling the gas control system 20 4 HOLE FIG 20 1 OUTSIDE AIR VENT EXTERIOR WALL FIG 21 ALUMINUM FLEX DUCT 21...

Page 18: ...UAL IS NOT FOLLOWED EXACTLY A FIRE OR EPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE 22 ATTACHING BURNER PAN AND PILOT Screw the fe male flare fitting on the end of the su...

Page 19: ...g Next cut several strips of diamond lath mesh 16 wide Place the lath strips against the inside Front Arch even with the Door Frame FIG 24 Using 15 8 washer head screws attach the lath to the Front Ar...

Page 20: ...ay not contain sand and cement Many indoor plasters are gypsum based Apply the 2nd coat using a trowel and then smooth out the plaster using water and a float or sponge When complete the 2nd coat will...

Page 21: ...ear the supplied Glowing Embers into dime sized pieces Place the pieces all around the burner holes on top of the burner pan making sure not to cover the burn holes where the gas will come out of See...

Page 22: ...T WHAT TO DO IF YOU SMELL GAS 1 Shut off gas to fireplace 2 Extinguish and flame 3 Go to a phone outside your home and call your gas supplier If you can t reach your gas supplier call the Fire Departm...

Page 23: ...a Frame hearth extension and are available in lengths of 2 to 10 Specify left or rights side when ordering Wood Storage Bin The Wood Storage Bin has an interior size of 24 wide x 12 high x 16 deep It...

Reviews: