Advanced RF Technologies, Inc.
24
4.
ALARMS
4.1
Message Board Alarms and Notifications
Table 4-1
Message Board Alarms and Notifications
Alarm
Alarm Description
Trigger Condition
AC Fail
AC Input is outside of
operating range
The power supply is not operating within specs. (4 seconds)
DC Fail
DC Output is outside of
operating range
The power supply is not operating within specs. (4 seconds)
Temperature
The module is above/below
the normal operating
temperature
The module is above the normal operating temperature. (4
seconds)
Over Temperature [Soft: 80~87
C, Hard: Above 87
C]
Current
PSU is providing more than
the max current
The power supply is not operating within specs. (4 seconds)
Over Current [Hard: Above 20A]
System Halt
The system is in a shutdown
state due to a hard fail alarm
The system is in a shutdown state due to a hard fail alarm. (10 cycles)
DSP Fault
The system has detected an
issue with the internal DSP
The system has detected an issue with the internal DSP chip. (Cannot
communicate with DSP)
OSC
Oscillation detected
Oscillation detected.
DL Signal not detected
DL signal is below the
specified level
DL signal is below the specified level. (default: -90dBm, 4 seconds)
DL Signal Low
DL signal is below the
specified level
DL signal is below the specified level. (default: -85dBm, 4 seconds)
Input Overload
Incoming in-band DL or UL
signal is too strong
Input signal is above the threshold. (4 seconds)
(Soft: DL -5dBm/UL -5dBm, Hard: DL +5dBm/UL +5dBm)
Out of band Overload
Incoming out-band DL or UL
signal is too strong
Out of band signal is above the threshold. (4 seconds)
(Soft: DL -5dBm/UL -5dBm, Hard: DL +5dBm/UL +5dBm)
Synthesizer Lock Fail
There is an issue with the
internal PLL
There is an issue with internal PLL. (4 seconds)
DL RF Power
Input + gain does not match
the output level (above
delta of 6 dB)
Input + gain does not match the output level.
(default delta of 6 dB)
Overpower
The output level is above the
max output levels
The output level is above the max output levels.
AGC On case (Soft: AGC Level + 1~2dB, Hard: AGC Level + >2dB)
AGC Off case (Soft: max output level + 1~2dB, Hard: max output level
+ >2dB)
VSWR
Power is being reflected
back to the repeater
Power is being reflected back to the repeater. Threshold = output
power - 8dB. For example, if the repeater is outputting 24dBm and
detects 16dBm of return power, then the VSWR will be triggered.
(Alarm will only trigger when the output power is 15dBm or greater)
Heartbeat
Heartbeat is sent out to the
NOC
Heartbeat sent at set interval.
Reboot
Soft reboot performed
Reboot is performed from the Control tab.
Factory setting
Factory default settings
restored
Factory setting is set from the Control tab.
Door
Door alarm set/clear
Door alarm set: Door open
Door alarm clear: Door close
4.2
External Alarms
The PSR-VU-9537-UBsupports dry contact alarms and can be connected to a fire alarm control panel. The user can program the
repeater to either create an open or closed circuit when an alarm is present in the system.
Summary of Contents for PSR-VU-9537-UA
Page 27: ...Advanced RF Technologies Inc 27 Figure 5 2 PSR ANN Repeater Mount ...
Page 37: ...Advanced RF Technologies Inc 37 7 2 Status Tab Figure 7 3 Status Tab ...
Page 41: ...Advanced RF Technologies Inc 41 7 3 Control Tab Figure 7 9 Control Tab ...
Page 57: ...Advanced RF Technologies Inc 57 Figure 11 2 PSR ANN Annunciator Mechanical Drawing ...
Page 58: ...Advanced RF Technologies Inc 58 Figure 11 3 ADRF BBL U Mechanical Drawing ...
Page 59: ...Advanced RF Technologies Inc 59 Figure 11 4 ADRF BBS U Mechanical Drawing ...