IRF3000 series
Instruction manual v1.1
28
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
7.5 Operating-mode related LED status displays
7.5.1 Boot-up
The boot-up process begins as soon as the device is supplied with power. The PWR LED flashes
slowly.
7.5.2 Resetting to default settings
The
Factory Default
button is used to reset the firewall back to the default factory settings at any time.
The Factory Default button must be pressed prior to the boot-up process and held down for approx. 10
seconds during the boot-up process. The PWR LED flashes rapidly while resetting to factory settings.
As soon as the PWR LED illuminates constantly, it is possible to access the web interface.
7.5.3 Firmware update
A firmware update can be performed via the web interface.
•
The
PWR-LED
flashes rapidly during a firmware update of the
firewall
. The actual update
procedure takes a few minutes. Initialisation begins after the update procedure has been performed
successfully. The PWR-LED flashes slowly during this process.
•
During a firmware update of the
mobile radio module
, the yellow WWAN-LED flashes with a
frequency of 5 Hz.