VMT8000 series
36
© ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen
8.4 RFID configuration
On delivery, the devices are preconfigured so that a test of the RFID functionality can be performed
without configuration.
Recommendation for use:
Check the functionality of your RFID reader using the following steps before
starting commissioning via software in order to exclude any possible
transport damages or other error sources.
Depending on hardware equipment, a MIFARE or LEGIC RFID reader is installed.
8.4.1 MIFARE
To test the RFID function, select the "
ads-tec RFID example application
" via the pre-installed
Configuration Center.
Recommendation for use:
Detailed information on the Configuration Center can be found in chapter
"Configuration Center".
Ads-tec RFID-Reader tool
This application is configured automatically, i.e. when the program is started, all COM ports are
searched for the RFID reader.
Fig. 7:
If an RFID reader was detected, the device cyclically queries to check whether a serial number (CSN)
was read. If a transponder serial number is read during this process, it is output directly on the user
interface.