background image

Patent No. US 8,856,780 CA 2759622

MODULE DIAGNOSTICS

 - 1 OF 1

TEST MODULE

LED 1 ST

ATUS

DIA

GNOSTIC

I

DURING MODULE PROGRAMMING

Flashing RED

Missing/wrong information from fi rmware or vehicle.

Solid RED

Module waiting for more vehicle information.

Flashing GREEN

Additional steps required to complete module programming.

Solid GREEN then OFF

Module correctly programmed.

OFF

No activity or module already programmed.

II

DURING TACH PROGRAMMING

1 GREEN fl ash

Tach signal programmed in Analog

2 GREEN fl ashes

Tach signal programmed in Data

3 RED fl ashes

No tach signal detected

4 RED fl ashes

System is in valet mode

5 RED fl ashes

Tach set for ‘VTS’.  No tach programming required

6 RED fl ashes

Tach set for ‘assumed start’.  No tach programming required

III

DURING REMOTE START

Flashing RED

Module incorrectly programmed.

Solid RED

Module incorrectly programmed.

Flashing GREEN

Module correctly programmed and operational.

Solid GREEN then OFF

Reset in progress.

OFF

Invalid ground when running status from remote starter.

IV

WITH IGNITION OFF

Flashing RED

Module incorrectly programmed or connected.

Solid RED

Module not programmed. Waiting for more vehicle information.

Flashing GREEN

False ground when running status from remote starter.

Solid GREEN then OFF

Reset in progress.

OFF

Module at rest and ready for a remote start sequence.

www.idatalink.com

Automotive Data Solutions Inc. © 2019

FLRSVW1

PAGE 10 OF 12

• 20190117

Summary of Contents for FLASHLOGIC FLRSVW1

Page 1: ...per installation of this product be that either damage to the vehicle itself or to the installed device This device must be installed by a certified technician Please review the Installation Guide carefully before beginning any work Patent No US 8 856 780 CA 2759622 PRODUCT GUIDE FLRSVW1 www idatalink com Automotive Data Solutions Inc 2019 ...

Page 2: ...ware for your vehicle and that you carefully review the install guide 1 866 427 2999 support idatalink com idatalink com support www 12voltdata com forum www facebook com groups idatatech TABLE OF CONTENTS Box Contents 3 Tach Programming Procedure 4 Remote Programming Procedure 5 Valet Mode Programming Procedure 6 Compatible Accessories 7 Online Module Settings 9 Module Diagnostics 10 Remote Start...

Page 3: ...EMPTY 05 EMPTY 05 EMPTY 06 BLUE WHITE BLACK DOT GWR OUTPUT 06 BLUE WHITE BLACK DOT GWR OUTPUT 07 BROWN BLACK DOT SIREN OUTPUT 07 BROWN BLACK DOT SIREN OUTPUT 08 WHITE PURPLE BLACK DOT 08 WHITE PURPLE BLACK DOT 09 PURPLE BLACK BLACK DOT RAP SHUTDOWN OUTPUT 09 PURPLE BLACK BLACK DOT RAP SHUTDOWN OUTPUT 10 WHITE BLACK BLACK DOT HORN OUTPUT 10 WHITE BLACK BLACK DOT HORN OUTPUT 11 BROWN BLACK BLACK DOT...

Page 4: ...rake pedal Press and release the module s programming button OR if the remotes are already programmed to the vehicle press and hold the start button of the remote for 2 5 seconds Wait LED 2 will flash GREEN See the Module Diagnostics page Release the brake pedal Module Programming Procedure completed www idatalink com Automotive Data Solutions Inc 2019 FLRSVW1 PAGE 4 OF 12 20190117 ...

Page 5: ... 1 AFTERMARKET REMOTE PROGRAMMING NOTES I All aftermarket remotes must be programmed to the RF Kit Refer to the RF Kit user guide for aftermarket remote features and programming procedures www idatalink com Automotive Data Solutions Inc 2019 FLRSVW1 PAGE 5 OF 12 20190117 ...

Page 6: ...n functional See RF kit user manual for alternate valet mode programming Time restriction Complete next step within 7 seconds Cycle ignition ON twice 2x OFF ON rapidly Press and release the BRAKE pedal three times 3x Parking Light will flash once 1x then will flash twice 2x Set ignition to OFF position Valet Mode Programming Procedure completed To exit valet mode repeat steps 1 to 5 www idatalink co...

Page 7: ...matic port NC TELEMATIC KIT accessory sold separately 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 WEBLINK MOBILE accessory sold separately MOBILE DEVICE PORT OBDII CONNECTOR 4 PIN BLACK CABLE MODULE WEBLINK PORT OBDII CONNECTOR WEBLINK CABLE required accessory sold separately WEBLINK CABLE COMPUTER USB PORT 4 PIN BLACK CABLE MODULE WEBLINK PORT OMEGA RF KIT RF KIT accessories sold separately ANTENNA NC...

Page 8: ...622 www idatalink com Automotive Data Solutions Inc 2019 FLRSVW1 PAGE 8 OF 12 20190117 COMPATIBLE ACCESSORIES 2 OF 2 RF KIT accessories sold separately DIRECTED XL202 RF KIT ADSHRNRSXL02 XL202 RF DECODER XL202 ANTENNA MODULE RF PORT ...

Page 9: ...ments Set transmitter AUX buttons controls MENU 5 Programmable outputs POC Set actions for programmable outputs MENU 6 Pulse Timer Output Configuration PTO Set duration for pulse timer outputs if used MENU 7 Input Configurations Set inputs for Auto by firmware Data Analog MENU 8 Output Configurations Set outputs for Auto by firmware Data Analog Programming options are avaible through Weblink and W...

Page 10: ...let mode 5 RED flashes Tach set for VTS No tach programming required 6 RED flashes Tach set for assumed start No tach programming required III DURING REMOTE START Flashing RED Module incorrectly programmed Solid RED Module incorrectly programmed Flashing GREEN Module correctly programmed and operational Solid GREEN then OFF Reset in progress OFF Invalid ground when running status from remote starter...

Page 11: ...N ERROR CODES NOTES Y NUMBER OF PARKING LIGHT FLASHES DIAGNOSTIC I WARNING The following applies only when the parking lights are connected and supported by the system 01 Engine tach signal is lost 02 Emergency brake is lost II If the engine shuts down after a remote starter sequence Press and hold the Trunk button and the Start button at the same time for 2 5 seconds when using a 1 WAY remote OR ...

Page 12: ...ect the M1 BLACK 8 pin connector and the M4 BLACK 20 pin connector PRESS AND HOLD the module s programming button while connecting the M1 BLACK 8 pin connector and the M4 BLACK 20 pin connector Wait LED 1 will flash RED RELEASE programming button LED 1 will turn RED for 2 seconds Module RESET completed Reconnect all connectors Repeat programming procedure Failure to follow procedure may result with...

Reviews: