background image

6

SPRINT - IP1546

GB

3.4  Installation with SPRINTBRAS articulated arm

Use  the  SPRINTBRAS  articulated  arm  for  doors  that  open 
inwards with deep recess max 185mm 

 The fastening distance of the automatic system in relation 

to the door wing can be between 185 mm and 45 mm.

-  

 

Adjust the length of the arms [E] and [F] so as to form an an

gle of 80÷90° in relation to the arm [M], with the door closed.

 

 

Note:  the  SPRINTBRAS  articulated  arm  is  assembled 
for door wings with left-hand or right hand opening arms 

-  

For distances between 45 mm and 20 mm, remove the 
arm [F] and fasten the arm [G] to the bracket [E] with the 
spacer and the screw supplied, so as to form an angle of 
80÷90° in relation to the arm [M].

3.5  Installation of door stop

Fasten the door stop (supplied as a mechanical opening stop) 
to the floor.

 

 

 

 

 

  

 

by rotating by 180 

degree's

Summary of Contents for DITEC Sprint IP1546

Page 1: ...THE DOORS Includes Silver Grey Cover On Off Rocker Switch Push Or Pull Arm Max Door Leaf Weight 70 kg Adl ZcZg n dg jaan VjidbVi X Ejh VcY d VX a in Dc D Id aZ hl iX ADSF DITEC SPRINT SWING OPERATOR M...

Page 2: ...2 SPRINT IP1546 Fig 1 Fig 2...

Page 3: ...HINERY DIRECTIVE Pursuant to Machinery Directive 98 37 EC the installer who motorises a door or gate has the same obligations as the ma nufacturer of machinery and as such must prepare the technical f...

Page 4: ...supply by means of the appropriate plug Connection to the grid is made with independent channels and separated from the connections to the command and safety devices 4 Mechanical opening stop 2 2 Auto...

Page 5: ...ve the casing and fasten the automation on the wall respecting the measurements indicated in the figu re refer to the hinge axis Bore the guide C and fasten it to the door Insert the sliding block D o...

Page 6: ...so as to form an an gle of 80 90 in relation to the arm M with the door closed Note the SPRINTBRAS articulated arm is assembled for door wings with left hand or right hand opening arms For distances b...

Page 7: ...tery that guarantees the conti nuous working even without a mains supply To charge the batteries connect the mains power and the batteries at least 30 seconds before starting the system To disconnect...

Page 8: ...e same time as the drive impulse During the closing operation the speed increases slightly to ensure the correct closing of the electric lock DIP3 Push Go Disabled Enabled DIP4 Direction selection The...

Page 9: ...onnect them again one at a time STOP contact open Check terminal 9 of the control panel The door is blocked by bolts and locks Make sure the wing can move freely The door opens but does not close Safe...

Page 10: ...nter the field of action of the motorised door or gate while in motion Do not obstruct the motion of the motorised door or gate as this may cause a situation of danger Do not allow children to play or...

Page 11: ...ual internal components for repair or replacement 5 Goods found not to be faulty may incur a testing fee handling charge of 10 00 plus vat 6 Physically damaged items will be rejected 7 Items may be re...

Page 12: ...tion switch manual hold open fully automatic Operation Electromechanical operation no risk of oil leakage Integrated damper prevents the door from slamming shut Active range EN3 EN6 Hold open time 1 3...

Page 13: ...notes...