background image

  

  

Installation Guide for the iHub-3000B-ADT, iHub-3001B-ADT 

 

     

  

Activating the Service with Security Panel 

Before continuing the activation process, you must make the hardware connections. Since each security 
panel is different, follow the instructions in the next section, "

Connecting the Hardware

", for the specific 

security panel you are installing. Then please follow the instructions in 

"Activating the Service" on 

page 

7

 for all security panels. 

Connecting the Hardware 

Follow the procedure in this section that applies to the security panel you are installing. 

Note:   

Do not connect the iHub gateway's power supply to an electrical outlet until you 

are instructed to do so by the activation wizard. If you power on the gateway before it is 
connected to the Internet, it cannot retrieve the information it requires on power up. If you 
have already done this, simply unplug it and continue with the following instructions.  

If you are installing a Touch Screen, do not connect it to a power source until you are 
instructed to do so by the activation wizard. 

 

To connect the gateway to the security panel RS422 interface: 

1.

 

Wire the RS422 interface unit (Automation Module or xSPIM) per manufacturer’s instructions.  
The RS422 module will connect to the Control Panel’s Keypad bus.) 

2.

 

The iHub connectors are labeled Tx+, Tx-, Rx+, and Rx-. The RS422 interface Module connectors 
are labeled the same but might include a/b instead of +/-. Using a standard 4-wire security cable, 
connect the ports on the gateway's RS422 bus to the RS422 interface Module as follows: 

iHUB Gateway 

RS422 interface module 

Tx+ 

Rx+ or RxD(+) 

Tx- 

Rx- or RxD(-) 

Rx+ 

Tx+ or TxD(+) 

Rx- 

Tx- or TxD(-) 

 

Locating the iHUB 

Internal Antenna units: 

1.

 

If the iHUB has no external antenna, the unit must be located on a horizontal surface (desk top).  
Try to place it at least 6 inches  from other communication or heat generating devices.  Do not 
place any electronics/communications devices on top of the iHUB.   

 

Summary of Contents for iHUB-3001B

Page 1: ...Copyright 2010 ADT Security Service Inc All rights reserved ISSUE 2 0 11 2010 iHUB 3001B iHUB 3001B ADT Installation Guide ...

Page 2: ...special configurations that may be required for the security system components Refer to the manufacturer s documentation for each device for those specifics Overview of the Installation Process The installation utilizes a streamlined process for setting up the system All components are individually activated and tested before being physically installed in their final locations whenever possible ...

Page 3: ... performed early in the install process so it can be done parallel with the site s installation activities To upgrade the software 1 On a computer connected to the Internet open a web browser and go to the activation URL portal adtpulse com activation 2 Enter your Installer username and password and click Sign In The activation wizard displays the Welcome screen 3 After reading the information on ...

Page 4: ...Select the type of security system panel you are installing and click Continue The Enter Activation Key screen appears 5 The iHub s current firmware will be displayed along with the Latest firmware version required Select upgrade now to begin the firmware upgrade ...

Page 5: ...rocess will take about 30 minutes to complete During this time other installation activities may be done 7 When the upgrade is complete the iHub will reboot and the LEDs will return to the green dark dark green state 8 The installer may sign out of the Activation wizard at this point ...

Page 6: ...unplug it and continue with the following instructions If you are installing a Touch Screen do not connect it to a power source until you are instructed to do so by the activation wizard To connect the gateway to the security panel RS422 interface 1 Wire the RS422 interface unit Automation Module or xSPIM per manufacturer s instructions The RS422 module will connect to the Control Panel s Keypad b...

Page 7: ...g ensure the antenna is positioned vertically for best performance Antenna Position Desk top iHUB Wall mounted iHUB Activating the Service To activate the service 1 On a computer connected to the Internet open a web browser and go to the activation URL portal adtpulse com activation 2 Enter your Installer username and password and click Sign In The activation wizard displays the Welcome screen 3 A...

Page 8: ...e installing and click Continue The Enter Activation Key screen appears 5 Enter the activation key and click Continue Note The activation key contains numbers from 0 9 and letters from A F There are no letters O or I The activation process begins and then the Select Service Options screen appears ...

Page 9: ...screen varies based on the security panel you are installing and the service options you selected on the previous screen 7 Follow the instructions on the screen and then click Continue A message displays a progress bar which indicates approximately how much longer the activation will take If an upgrade is required the activation application performs the upgrade automatically If the power light bli...

Page 10: ...ccount screen appears Continue with Creating a User Account on page 10 If the customer already has a user account enter their username on the right side of the screen and click Continue Skip the next section and continue with Configuring Site Information on page 11 Creating a User Account For customers who do not yet have a user account you must create one The user account enables you to complete ...

Page 11: ...e customer s email address will also be their username Click Continue The Site Information screen appears Continue with Configuring Site Information on page 11 Configuring Site Information When you click Continue on either the user selection screen or the Create User Account screen the Site Information screen appears ...

Page 12: ... must match the same access code in the ADT Pulse portal For example if the user access code is 1234 not recommended the ADT Pulse setting must also be 1234 or remote control will not be possible The installer should inform the customer that if they ever change their keypad user code they must also change the code in the ADT Pulse web portal A message informs you that the service is now active Not...

Page 13: ...gn In The web portal launches and displays a site status message at the top of the page indicating that the site is in install mode Continue with the installation and set up referring to the ON LINE Help and instructions NOTE For Honeywell Panels set zone types for all sensors Follow the on screen process Under System Tab Manage Devices ...

Page 14: ... and memory SoC Broadcom 5354 SDRAM DDR 32 MB Nor Flash 32 MB Connectors DC Power Jack Screw Terminal for RS232 RS422 2 RJ 45 for Ethernet LAN and WAN 2 USB for external USB device LED and Button LED Power Broadband Devices Button Reset Sync Antenna 1 WiFi External 5 db antenna 1 WiFi internal antenna optional 1 Z Wave internal antenna Power Consumption 12 DC Max 10 5W Compliance FCC CA Power Supp...

Page 15: ...s However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separati...

Reviews: