GENERAL INFORMATION

 

The 6150ADT is an addressable remote keypad designed for 
use with ADT control panels. Addresses are set via the 
keypad keys.  

Keypad keys are continuously backlit for convenience.  

NOTE: 

Permanent display backlighting is an option on some 

controls (refer to the control panel’s instructions for 
details). 

KEYPAD DISPLAYS AND LEDS 

The keypads have the following display features: 

 

Fixed Word Display 

 

Two-Digit Zone Identifier 

The following table identifies the keypad’s LEDs and 
associated functions: 

LED Function 

Red 

Lights when the system is armed in any mode. 

Green 

Lights when the system is "ready" to be armed. 

SPECIAL FUNCTION KEYS 

The Keypad also features function keys.  These keys may be 
programmed for panic alarms or other special functions such 
as macros. Refer to the control panel’s Installation & Setup 
Guide for details.  

 

Function keys must be held down for at least 2 

seconds to activate an alarm; key pairs are activated 

immediately.

 

 

 

Function Keys

 

Key Pairs 

A  

[1] and [

B  

[

] and [#] 

[3] and [#] 

D  

WIRING AND INSTALLATION

 

Keypads can be surface mounted directly to a drywall or to a 
single- or double-gang electrical box.  

 1.  Remove the case back by pushing up the two "snaps" 

along the keypad’s bottom edge and pulling the case 
apart.  See Figure 1. 

2.  Route wiring from the control panel through the opening 

in the case back. 

3.  Mount the case back to a wall or electrical box.  

4.  Wire directly from the keypad’s terminal block to the 

terminal block on the control board. (See Wiring Table.)  

WIRING TABLE 

Keypad 

Control Panel 

Wire Color 

G Data 

In 

Green 

–   

– Aux Pwr (GND) 

Black 

+ Aux. Pwr 

Red 

Y  

Data Out 

Yellow 

5.  Re-attach the keypad to the case back. 

6.  Remove clear protective film from LCD display. 

 

6150ADT-005-V0

MOUNTING RELEASE SNAPS

(Remove case back by pushing up the 2 "snaps" along

the keypad's bottom edge and pulling the case apart.)

SIDE VIEW

A

B

C

D

ARMED

READY

1

2

3

4

5

6

7

8

9

0

#

STAY

BYPASS

CHIME

INSTANT

AWAY

CODE

TEST

OFF

READY

 

Figure 1 – 6150ADT Keypad 

SETTING THE KEYPAD ADDRESS 

The keypad can either be set for an address of 00-30 or for 
non-addressable mode (31).  The default keypad address is 
31.  Refer to the control panel's Installation & Setup Guide 
for valid address settings for your control. 

To change the keypad address, proceed as follows: 

1.  Enter the address mode:  Power up the keypad.  Within 

60 seconds of power-up, press and hold down the [1] and 
[3] keys at the same time for 3 seconds.  (If unable to 
enter the address mode, power down, power up, and try 
again.) 

 

The current keypad address is displayed, and the cursor 
is under the "tens" digit.  If 10 seconds pass with no key 
entry, the keypad automatically exits the address mode.  
You must power down, power up, and start the address 
mode again. 

 

The keypad will not enter the address mode if the 

control panel is in the programming mode. 

2.  Set the current address to "00":  Press [0] to clear the 

current "tens" digit.  The cursor moves to the "ones" digit 
position.  Press [0] to clear the current "ones" digit.  The 
cursor moves back to the "tens" digit position. 