38
Reset is enabled from Programming Mode by pressing 981 twice within 5 seconds.
If the Engineer or Master User Code has been lost they can be defaulted separately from
the rest of the system. This is done from Day Mode:
• Power down the control.
• Re-power the control.
• Hold down the
Ö
and # keys together until two beeps are heard.
• The Engineer Code is now 9090 and the Manager Code is 1234.
Group 9 — Option 9 Show Software Version
Enter 991 to display a three digit version number.
Group 0 Communications
Group 0 — Option 1 Technistore Version
This option is for use with Technistore reset. The engineer can programme the Technistore
Version Number with a valid range of 000 to 255.
To programme the Technistore Version Number:
• Enter Programming Mode.
• Press 0, then 1, then enter the Technistore version number.
This option defaults to 002.
Note: The Technistore Version should be selected after discussion with the Alarm
Central Station (ARC).
Group 0 — Option 2 Verified Alarm Time Window
This option represents the necessary time period between the activation of two separate
zones before a verified alarm signal is sent to the ARC.
0.
45 mins
1.
10 mins
2.
20 mins
3.
30 mins
This option defaults to 3 (30 mins).