46
Note: The master user code defaults to 1234, the Engineer Code defaults to 9090.
The master user code can reprogramme the other seven user codes. Only the master user
code can be used to reprogramme the master user code.
Only the Engineer code can be used to re-programme the Engineer Code.
Each user can re-programme their own code.
Programming New User Codes
To programme a new User Code, enter the Master User Code, select the code option by
pressing 8, press the appropriate key to select the User Code (2 — 8) and enter the new
code number.
Example: To programme User Code 2 as 2626:
• Enter the Master User Code.
• Press: 8 2 2626.
• Two beeps confirm that the new code has been accepted.
• User Code 2 is now 2626.
Removing a User Code from the System
Users can remove their own user code from the system. To remove their own User Code,
enter code, select the codes option by pressing 8, press the appropriate key for your user
number and press the
Ö
key.
Example: To delete User Code 2 from the system User 2 should:
• Enter user 2’s User Code.
• Press: 8 2
Ö
.
• Two beeps confirm that the User Code has been deleted.
• User two has been removed from the system.
Note: The Master User Code (User 1) can delete the other seven User Codes. The
Master User Code cannot be deleted. If the engineer deletes the engineer code,
it can be rectified by defaulting the code.
Enabling/Disabling the Chime Function 9 ( )
Any zone can be programmed to Chime (two beeps from the keypad and internal sounder)
when it is activated.
Enabling the Chime Function on Zones
To enable the Chime function on a zone or zones: enter your User Code, select the
Chime option by pressing 9 and press the appropriate keys for the zones you wish to
chime.
Example: To enable the Chime function on zones three and five:
Summary of Contents for ACCORD XPC
Page 1: ...Installation Manual ...
Page 2: ......
Page 12: ...6 ...
Page 48: ...42 ...
Page 56: ...50 ...
Page 61: ...55 Accord xpC July 2001 ...
Page 62: ...56 IE1 1230 63 Issue D ...