– 11 –
Account information is provided by the central station administrator.
PROMPTS ENTRY
OPTIONS
DESCRIPTION
22
Primary Subsys #
(??)_
[00-99]
Enter the primary subsystem this unit is a
member of.
23
Primary Group #
(???)_
[000-999]
Enter the primary group number this unit is
a member of.
24
Primary Sub ID
(????)_
[0001-9999]
Enter the 4-digit subscriber account number
for the primary central station, 0001-9999.
25
Device Address
(03)_
[01-30]
The GSMVL-ADT communicates with the
panel as a Long Range Radio (LRR) device.
Enter ECP device address 03.
NOTE:
When programming the control, enable the
LRR output.
26
Remote AccessY/N
(N)_
[Y], [N]
Press [Y] to allow the end user to access their
system via website.
If not enabled, skip to Prompt 28
27
Keypad Address
(28)_
[01-30]
This address must be programmed if using
Remote Access. For the Lynx Plus and ADT
Safewatch QuickConnect 3000 panel, the
address must be 01.
28
Supervision
(24 Hours)_
•
30 Day
•
24 Hour
•
None
The GSMVLP-ADT will send one status
message in the programmed interval. When
the Central Station Receiver receives this
message, it will generate a periodic RF
transmission (E603) and pass this message to
the automation system. It is the
responsibility of the automation system to
alert the CS when that message is failed to be
delivered.
Press the [space] key to scroll
through choices.
UL NOTE:
Must be 24 hour.
29
Old Alarm Time
(10 Minutes)_
•
10 Minutes
•
15 Minutes
•
30 Minutes
•
1 Hour
•
2 Hours
•
4 Hours
•
8 Hours
•
12 Hours
•
24 Hours
The old alarm time sets how long an
undeliverable alarm is retried for delivery to
the central station. If the message is not
validated, it is retried until the old alarm
time is reached or the message is validated.
Press the [space] key to scroll through
choices.
UL NOTE:
Must be 10 minutes.