PROMPTS ENTRY 

OPTIONS 

DESCRIPTION 

30 

 

GSM Flt Time    
(00 mins)_ 

 

 

[00-99] 
[00] = panel is 
NOT notified 

 

In the event the module detects a 
communication path failure, enter the time 
delay (in minutes) before the module notifies 
the control panel with a trouble message.  
The control panel can then notify the central 
station. Enter 00 if you do not want this 
module to notify the control panel of a 
communication path failure. 

UL NOTE:

 Must be one (01) minute. 

31 

 

Review?  Y/N 
 

 

 

[Y] = review 
[N] = exit

 

Reviewing Programming Mode Entries

 

To review the programming options (to 
ensure that the correct entries have been 
made), press [Y].  The programming prompts 
are displayed again. Use the up/down arrow 
keys to scroll through the program fields 
without changing any of the values. If a value 
requires change, simply type in the correct 
value. When the last field is displayed, the 
“REVIEW?” prompt again appears. 

To exit the programming mode

, press [N] 

in response to the "REVIEW?" prompt, and 
refer to 

Exiting Programming Mode

 

paragraph at the end of this section. 

 

ECP Status Codes 

The GSMVLP-ADT sends status messages to the control panel to indicate general failures. The control 
will display “FAULT 103” if any of the events listed below should occur. In addition, the Contact ID 
codes (listed in Appendix A) for these conditions are sent to the central station by the module. 

 

GSMVLP-ADT loses communication with control panel. 

 

GSMVLP-ADT lost contact with AlarmNet. 

 

GSMVLP-ADT is not registered; account not activated. 

 

GSMVLP-ADT shutdown. 

Exiting Programming Mode 

To exit the programming mode, press [N] in response to the "REVIEW?" question. Then press [Y] to the 
"Exit Prog Mode?" question. Upon exiting, the message “Checking Root File TX Path” will be displayed, 
and the configuration file at the server is updated to log the changes made. When complete, the 
message "DONE" is displayed to indicate the file was successfully uploaded.  

 

If critical configuration changes were made, such as the mode of operation, the GSMVLP-
ADT will reset to ensure that the programming features are enabled. 

If the file is not successfully uploaded, one of the following prompts will be displayed. Follow the steps 
shown  below, until the upload is successful. 

 

Summary of Contents for GSMVLP-ADT

Page 1: ...GSMVLP ADT GSM Module with 2 Way Voice Installation and Programming Guide 800 04954 1 11 09 Rev A...

Page 2: ...P Mode Programming 7 Setting up the Multi Mode Feature 9 Configuring Multi Mode 9 Setting up the Remote Access Feature 10 Enabling Remote Access 10 Selecting the User Interface 11 ECP Status Codes 12...

Page 3: ...and central station via GSM Sends reports in Contact ID format Supports remote control of alarm system via Remote Services Feature Fully powered primary and backup battery from the control The GSMVLP...

Page 4: ...d floor Opening the ADT QuickConnect 3000 Control and Installing GSMVLP ADT 1 Install the provided IC label P N 800 05101 on the control s back case as shown on Figure 2 GSMVLP 005 V0 CONTAINS TRANSMI...

Page 5: ...cable provides DC power and ground for the module and ECP connections 6 Make the wiring connections and install the control in accordance with the ADT QuickConnect 3000 Installation Instructions 7 Re...

Page 6: ...you are already signed up for this service go to https services alarmnet com AlarmNetDirect userlogin aspx If you are not signed up for this service click on Dealer Sign Up Log in and follow the on sc...

Page 7: ...FT KEY FUNCTION BS ESC BS Press to delete entry ESC Press to quit program mode also can reset programming defaults Scroll down programming Scroll up programming N Y N Press for NO answer Y Press SHIFT...

Page 8: ...ring center can remotely block access to local device programming If this has been done the following prompt appears Access to Prog Mode Denied Table 2 Programming the GSMVLP ADT Module NOTE The defau...

Page 9: ...therwise the Exit Prog Mode prompt is displayed directly 8 Exit Prog Mode Y N _ Y N ESC Exits program mode Press N to go back to Prompt 3 Press ESC to load factory defaults Refer to the Exiting Progra...

Page 10: ...5 It MUST be programmed with a valid IP address 17 CS1 Port 443 _ 0 65535 Enter the internet port of the first CS receiver that the device will report to 18 CS2 IP 255 255 255 255_ 12 digit IP Address...

Page 11: ...ed if using Remote Access For the Lynx Plus and ADT Safewatch QuickConnect 3000 panel the address must be 01 28 Supervision 24 Hours _ 30 Day 24 Hour None The GSMVLP ADT will send one status message i...

Page 12: ...graph at the end of this section ECP Status Codes The GSMVLP ADT sends status messages to the control panel to indicate general failures The control will display FAULT 103 if any of the events listed...

Page 13: ...key refer to the Programmer Keyboard Commands section Setting Factory Defaults To reset the programming options to factory default values press ESC at the Exit Prog Mode prompt Set Default Y N_ Press...

Page 14: ...pace key to go to the next field Press the backspace key to go to the previous field SCID xxxxx xxxxx xxxxx xxxxx SCID Display Displays the identification number assigned to the SIM card SCID in this...

Page 15: ...ce key to go to the previous field Cell BaseSt Chan xxxxx x xxx GSMVLP ADT Status Display Screen 3 Cell Base Station ID BaseSt Base Station Antenna Sector Chan Control Channel in use Press the space k...

Page 16: ...TE If the GSMVLP ADT module is not initialized when you enter this command the following screen will be displayed Cannot Upload Try Later _ 0 Force Server Update Y N Wait for the RSSI LEDs to light in...

Page 17: ...t the minimum required signal strength for installation exists between the module and the receiving tower Refer to Figure 8 Table 3 Status and Signal Strength LED Operation LED COLOR LED DESCRIPTION G...

Page 18: ...onditions listed below Table 4 GSMVLP ADT Central Station Messages Alarm Condition ECP Mode Alarm Code ECP Mode Restore Code Power On Reset E339 C0803 ECP Supervision E355 C0000 R355 C0000 Communicati...

Page 19: ...ripheral devices consists of a four wire data bus power data in out GPRS General Packet Radio Service GSM Global System for Mobile communications which is an international standard for digital mobile...

Page 20: ...0 SPECIFICATIONS 1 Physical Dimensions 5 625 x 2 25 2 Electrical Input Voltage 12VDC nominal powered by the ADT QuickConnect 3000 Control Panel Quiescent Current 40mA Peak Current During Transmit 650m...

Page 21: ...21 NOTES...

Page 22: ...22 NOTES...

Page 23: ...23 NOTES...

Page 24: ...ADT Security Services Inc One Town Center Road Boca Raton FL 33486 Copyright 2009 800 04954 1 800 04954 1 11 09 Rev A...

Reviews: