ADT-09 Series Motion Control Card
49
and remove sound card, network card, etc., to ensure that the board is
properly tightened and installed. Then, restart it for verification.
5)
If you check as per the above steps and the system still cannot detect the
board, try to seek for technical support or consult us to ask for replacing
the board.
5.2.
Control card initialization failure
There are many reasons for the initialization failure of control card. The
problem description and recommended solutions are listed below.
5.2.1.
WinIO initialization failed, Error Code 9
Possible cause
Run the sample application not as an administrator
Solution
1. Close the sample application currently run by right clicking and choose to
Run as administrator”.
2. Close the sample application currently run by right clicking Properties -->
Compatibility --> Privilege Level, and run this program as an administrator.
3. Upgrade the current user system level to the administrator
5.2.2.
PCI bridge failed, Error Code 10
Possible cause
1. The PCI bridge is in poor contact with the board, and the PCI slot needs
to be cleared or partially damaged.
Solution
1. Shut down and take out the control card; clean the PCI slot, and clear the