Chapter 3
Function and Operation
3-24
Figure 3.2.3.3.3 Align with X axis as the reference axis
1) As shown in the above figure, point A is the start point of the cutting torch; move the cutting torch to point
A and press F1 to confirm, point A will be set as the start point of calibration; then press direction key to move to
point B and press F2 to set it as the end point of the calibration, thus the angle of inclination of the steel plate will
be calculated, and finally press F3 to confirm. If the align angle is set to be saved in settings, the angle will be
saved for next use.
2) In such case the Shape will be rotated at an angle accordingly. The positions of the Shape to be processed
and the steel plate are as follow:
Figure 3.2.3.3.4 Result of align with X axis as the reference axis
3) If the steel plate is inclined to left as shown in the figure below, then the align method is as follow:
Figure 3.2.3.3.4 Right inclination align with X axis as the reference axis
Similarly, move the cutting torch to point A and press F1 to set point A as the start point of the align; then
press direction key to move to point B and press F2 to set it as the end point of the calibration, thus the angle of
inclination of the steel plate will be calculated, and finally press F3 to confirm. The positions of the Shape to be
Summary of Contents for ADT-HC8200
Page 5: ......
Page 11: ......
Page 22: ...Chapter 2 2 12 Figure 2 4 1 1 2 Side view of AIO controller...
Page 25: ......
Page 93: ......