- 180 -
not reset.
061
LED Conf in RESET 00 ~ 31
062
LED Conf in RESET 32 ~ 63
063
LED Conf in RESET 64 ~ 95
064
LED Conf in RESET 96 ~ 127
065
LED Conf in RESET 128 ~ 159
066
LED Conf in RESET 160 ~ 191
067
LED Conf in RESET 192 ~ 223
Range :
0x00000000~0xFFFFFFFF
Unit
:
Authority
:
Super
Admin
Default :
0
Effective
time
:
Instant
Note
:
Used to configure the IO that the system needs to reset when there is
alarm. 0: No; 1: Yes
Use binary system to configure in positions.
For example: P6.56:10, is 00000000 00000000 00000000 00001010 in
binary system;
which indicates that among OUT32 ~ OUT63, OUT33 is reset when the
system resets or alarms, OUT35 turns off, while other output ports are
not reset.
068
Power-on Output Open 00~31
069
Power-on Output Open 32~63
070
Power-on Output Open 64~95
071
Power-on Output Open 96~127
072
Power-on Output Open 128~159
073
Power-on Output Open 160~191
074
Power-on Output Open 192~223
Range :
0x00000000~0xFFFFFFFF
Unit
:
Authority
:
Super
Admin
Summary of Contents for CNC9 Series
Page 1: ...ADTECH 9 Series CNC Maintenance Manual ...
Page 18: ...ADTECH9 Series CNC Maintenance Manual 13 2 2ADTCNC99 and 98 series system LCD keypad ...
Page 19: ...ADTECH9 Series CNC Maintenance Manual 14 ...
Page 45: ...ADTECH9 Series CNC Maintenance Manual 40 ...
Page 216: ...ADTECH9 Series CNC Maintenance Manual 211 11 3 2 Power connection diagram ...
Page 217: ...ADTECH9 Series CNC Maintenance Manual 212 11 3 3 Servo driver connection diagram ...
Page 218: ...ADTECH9 Series CNC Maintenance Manual 213 11 3 4 Step connection diagram ...
Page 219: ...ADTECH9 Series CNC Maintenance Manual 214 11 3 5 IO electrical connection diagram ...
Page 220: ...ADTECH9 Series CNC Maintenance Manual 215 ...