User Manual of TV5600-B01 Series Dispensing Control System
88
Appendix II: List of Processing Instructions
Instr
uctio
n ID
Instructionn
ame
Function
1 Start point
Other axes except the Z axis are first set to the start position, then the Z axis
is lowered to the start position and the valve is opened
1)
XYZABC coordinates: Coordinates of each axis
2)
XYZABC enable: Whether each axis participates in motion
3)
Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
4)
Use default speed: Select Yes to run at the speed set in the file
parameter, or else use the speed set in speed ratio * file parameter
5)
Speed ratio (%): This value is meaningful when the default value is not
used as above
6)
Delayopening mode: By default, the delayopening time in the file
parameter is used, or else the time set below is used
7)
Delayopening time: Use this time when the delay opening mode is in
delay mode, or else this value is meaningless
8)
Advance opening time: Use this time when the delay opening mode is in
advance mode, or elsethis value is meaningless
2 End point
After XYZ moves to the end point, the valve is closed and the Z axis is lifted to
the needle height
1)
XYZABC coordinates: Coordinates of each axis
2)
XYZABC enable: Whether each axis participates in motion
3)
Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
4)
Use default speed: Select Yes to run at the speed set in the file
parameter, or else use the speed set in speed ratio * file parameter
5)
Speed ratio (%): This value is meaningful when the default value is not
used as above
6)
Use default advance closing distance: Select Yes to use the
advanceclosing distance gun file parameters, and select Noto use the
following advanceclosingdistance
7)
Advance closingdistance: This value is meaningful when the default
value is not used as above
8)
Default needle height: Select Yes to use the needle height in the file
parameters, and select No to use the needle height below
9)
Needle height: This value is meaningful when the default value is not
used as above
3 Straight line
XYZ moves to the specified position by linear interpolation, and other axes
follow the movement to the specified position
1)
XYZABC coordinates: Coordinates of each axis
Summary of Contents for DJ1600V1-A01
Page 1: ...I TV5600 B01 Series Dispensing Control System User Manual ...
Page 2: ...User Manual of TV5600 B01 Series Dispensing Control System 2 ...
Page 15: ...User Manual of TV5600 B01 Series Dispensing Control System 15 Front view Side view Side view ...
Page 47: ...User Manual of TV5600 B01 Series Dispensing Control System 47 ...
Page 123: ...User Manual of TV5600 B01 Series Dispensing Control System 123 ...