User Manual of TV5600-B01 Series Dispensing Control System
89
2)
XYZABC enable: Whether each axis participates in motion
3)
Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
4)
Use default speed: Select Yes to run at the speed set in the file
parameter, or else use the speed set in speed ratio * file parameter
5)
Speed ratio (%): This value is meaningful when the default value is not
used as above
4 Single point
Other axes except the Z axis are first set to the single point position, then the
Z axis is lowered to the start position and the valve is opened. Afterdelaying
the specified dispensing time, the valve is closed, and the Z axis is lifted to
the needle height
1)
XYZABC coordinates: Coordinates of each axis
2)
XYZABC enable: Whether each axis participates in motion
3)
Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
4)
Use default speed: Select Yes to run at the speed set in the file
parameter, or else use the speed set in speed ratio * file parameter
5)
Speed ratio (%): This value is meaningful when the default value is not
used as above
6)
Delay opening mode: By default, the delay opening time in the file
parameter is used, or else the time set below is used
7)
Delay opening time: Use this time when the delay opening mode is in
delay mode, or else this value is meaningless
8)
Advance opening time: Use this time when the delay opening mode is in
advance mode, or else this value is meaningless
9)
Default needle height: Select Yes to use the needle height in the file
parameters, and select No to use the needle height below
10)
Needle height: This value is meaningful when the default value is not
used as above
11)
Default single point time: select Yes to use single point time in file
parameters, or else use the following single point time
12)
Single point time: This value is meaningful when the default value is not
used as above
5
Clockwise
arc
XYZ moves to the specified position in clockwise arc interpolation mode, and
the arc radius and the end point coordinates need to be given.Other axes are
synchronized to move to the specified position
1)
Arc type: Arc size
2)
Plane of the arc: Determine the arc interpolation axis
3)
Arc radius
4)
Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
6 Inverse arc
XYZ moves to the specified position in clockwise arc interpolation mode, and
the arc radius and the end point coordinates need to be given. Other axes are
synchronized to move to the specified position
Summary of Contents for DJ1600V1-A01
Page 1: ...I TV5600 B01 Series Dispensing Control System User Manual ...
Page 2: ...User Manual of TV5600 B01 Series Dispensing Control System 2 ...
Page 15: ...User Manual of TV5600 B01 Series Dispensing Control System 15 Front view Side view Side view ...
Page 47: ...User Manual of TV5600 B01 Series Dispensing Control System 47 ...
Page 123: ...User Manual of TV5600 B01 Series Dispensing Control System 123 ...