Chapter 3. Configuration
3-4
MX2800 STS-1 User Manual
61200659L1-1
signal or reception of AIS will cause the unit to enter hold-over
mode. The STS-1 receive signal must be valid for at least 10
seconds for the unit to exit hold-over mode and restore loop timing.
When the unit is configured for
F
REE
-R
UN
timing mode, timing is
derived from a +/-20 ppm internal reference providing a SONET
Minimum Clock (SMC).
Setting the unit to
E
XTERNAL
timing mode configures the unit to
derive clocking from one of the two external sources selected in the
P
RI
E
XT
. C
LOCK
and
S
EC
E
XT
. C
LOCK
options. These two entries
select which of the 28 active T1/E1 ports will be used as the
external clock source. The external clock source may be disabled (if
only one source exists, or no external clock sources are desired). A
valid clock source is one on which neither LOS or AIS conditions
exist. The selected T1/E1 may be a data carrying tributary. When
both sources are configured, failure of one source will cause the
unit to switch to the other source (if it is a valid source). Failure of
both sources will cause the unit to enter hold-over mode. At least
one external clock source must be valid for at least 10 seconds for
the unit to exit hold-over mode and restore external clock timing.
XCV Threshold
The
XCV T
HRESHOLD
(excessive code violations threshold) sets a
limit on code violations accepted by the unit before it switches
controller cards. If set to
D
ISABLED
, code violations will not cause
the unit to switch controller cards. The threshold limits are
described in the following chart:
Switching between
P
RI
mary and
S
EC
ondary external clock sources
is non-reverting.
Summary of Contents for 1200287L1
Page 10: ...x MX2800 STS 1 User Manual 61200659L1 1...
Page 18: ...Table of Contents xviii MX2800 STS 1 User Manual 61200659L1 1...
Page 22: ...List of Tables xxii MX2800 STS 1 User Manual 61200659L1 1...
Page 90: ...Chapter 3 Configuration 3 44 MX2800 STS 1 User Manual 61200659L1 1...
Page 134: ...Chapter 6 Diagnostics 6 12 MX2800 STS 1 User Manual 61200659L1 1...
Page 140: ...Chapter 7 Circuit and Network Redundancy 7 6 MX2800 STS 1 User Manual 61200659L1 1...
Page 146: ...Chapter 8 Power Loss Recovery 8 6 MX2800 STS 1 User Manual 61200659L1 1...
Page 160: ...Chapter 9 Transaction Language 1 TL1 9 14 MX2800 STS 1 User Manual 61200659L1 1...
Page 164: ...Appendix A Pinouts A 4 MX2800 STS 1 User Manual 61200659L1 1...
Page 168: ...Appendix B Specifications Summary B 4 MX2800 STS 1 User Manual 61200659L1 1...
Page 174: ...Appendix C Acronyms Abbreviations C 6 MX2800 STS 1 User Manual 61200659L1 1...