background image

2

Issue 14, April 2003

64200376L1-5A

A compact, NEBS-compliant cabinet suitable for the 
customer premises or the central office provides added 
safety and reliability. The 2U design uses little rack 
space. When wall mounted, the 8.5-inch by 11-inch 
chassis occupies a space the size of a piece of notebook 
paper. Two Total Access 850 systems can be mounted 
side-by-side in either 19-inch or 23-inch relay racks. 
Preconfigured packages are available. 

Features

The Total Access 850 includes the following features:

• T1/FT1 integrated access
• TDM to ATM migration (RCU)
• Modular network interface (RCU)
• Integrated IP router (RCU)
• V.35 Nx56/64 DTE interface
• DSX-1 card for Dual T1 support (RCU)
• TR-08 signaling support
• Analog FXS and FXO voice expansion (four per card)
• SNMP management (RCU)
• NEBS and UL 1950 compliance
• Industry leading 10-year warranty

Functional Description

The Total Access 850 System comprises the chassis, 
common cards, and access modules. Associated with 
the system are additional elements including an AC to 
DC power supply and battery charging unit and a bat-
tery pack for backup power.

External AC and DC Power. 

The ADTRAN AC/DC 

Power Supply/Battery Charging unit receives its 
power from a standard 115 VAC outlet. The PSU 
supplies a constant  -48 VDC to the voice cards. The 
power supply battery charging circuit maintains the 
battery pack at peak charge. In the event of an AC 
power failure, the battery backup circuit automatically 
provides battery power to the PSU for up to 8 hours. 
When AC power is restored, input power automatically 
returns to the AC supply and the battery charging 
circuit will recharge the battery to peak. 

On the Total Access 850 chassis, the incoming power 
termination point is on either of two backplane 
connections: P7 or P6. (See Figure 2.) Both sources 
connect 

directly to the PSU. Connector P6 is used when the 
chassis is powered by the ADTRAN AC/DC Power 
Supply unit (P/N 1175043L2) which mounts externally 
to the chassis. Connector P7 is used when -48 VDC is 
available on site and screw-type terminal connections 
are required.

Figure 2.  Total Access 850 Backplane

PSU. 

The Power Supply Unit supplies -48 VDC and 

20 Hz ringing voltage to the RCU, BCUs, and access 
modules. The PSU converts -48 VDC input to the 
required voltages needed to operate all common units 
and access modules. The ring generator circuit provides 
20 Hz ring voltage to the analog access modules.

The PSU faceplate (see Figure 1 on page 1) shows the 
following: a ring enable button, a power LED, a ring 
LED, a bank alarm LED, and an alarm cutoff (ACO) 
pushbutton switch. The separately fused ring generator 
supplies up to 20 REN to the access modules.

BCU. 

The Bank Controller Unit is a common module 

plug-in unit with a built-in CSU. The BCU provides all 
control functions for the Total Access 850 common units 
and all individual access modules. A faceplate 

ADMIN

 

DB-9 provides access for a VT 100 terminal for screen 
menu provisioning, and bantam test jacks provide 
transmit and receive monitoring. An additional 

TEST

 

DB-9 provides timing for DS0 test equipment. Faceplate 
LEDs show status information for the network and 
Fractional (DSX-1) T1 (L2 only). The unit consists of a 
main circuit board and daughter card and inserts 
directly in the controller slot on the Total Access 850 
shelf. An 8-position DIP switch is mounted on the 
daughter card and is used for T1 provisioning and 
clocking. 

RCU. 

The Router Control Unit is a dual board assembly 

that provides the network interface. The RCU can 
provision, test, and provide status for any card in the 
channel bank. A faceplate 

CRAFT

 DB-9 provides access 

for a VT 100 terminal for screen menu provisioning, and 
bantam test jacks provide transmit and receive 
monitoring. Faceplate LEDs show status information 
for the network, V.35, and Ethernet ports.

WARNING

On Total Access 850 installations that do not use 
all chassis slots, UL 1950/NEBS requires that the 
empty slots must have a Total Access 850 blank unit 
(part number 1175099L1) installed in the opening.

Summary of Contents for 1200375L1

Page 1: ...tomer s premises The Total Access 850 system benefits integrated communications providers such as CLECs ILECs and ISPs who require a customer premises device that integrates voice and data functions and provides a viable migration path from TDM to packet based technology The Total Access 850 features remote management an integrated IP router and special services slots Figure 1 Total Access 850 The...

Page 2: ...y unit P N 1175043L2 which mounts externally to the chassis Connector P7 is used when 48 VDC is available on site and screw type terminal connections are required Figure 2 Total Access 850 Backplane PSU The Power Supply Unit supplies 48 VDC and 20 Hz ringing voltage to the RCU BCUs and access modules The PSU converts 48 VDC input to the required voltages needed to operate all common units and acce...

Page 3: ...ry equipment grounding conductor shall not be smaller in size than the ungrounded branch circuit supply conductors The supplementary equipment grounding conductor shall be connected to the product at the terminal provided and shall be connected to ground in a manner that will retain the ground connection when the product is unplugged from the receptacle The connection to ground of the supplementar...

Page 4: ...s 1 Unscrew the access cover hold down screw 2 Slide the access cover down slightly to disengage the lock tabs from their slots 3 Identify the wire wrap pins designated for use and make the connections starting with the pins closest to the exit port to avoid wiring interference as work progresses 4 If alternate power connection to P7 is to be used make those terminal connections last 5 Carefully r...

Page 5: ...ioned on the RCU Power Connection There are two power connections on the backplane a modular DC plug P6 and a three lug terminal strip P7 Refer to Figure 2 on page 2 The primary connection is the modular plug which receives 48 VDC from the ADTRAN power supply battery charging unit P N 1175043L2 The alternate connection is screw terminal P7 which can be used if 48 Vdc is available as in central off...

Page 6: ...ate If the 3 Amp power fuse on the PSU trips the 48ALM relay will close providing a 48 VDC signal on that pin This alarm cannot be overridden by the ACO pushbutton Refer to Table 3 on page 6 for alarm notifications Table 2 Wire Wrap Identification Figure 7 Office Alarm Connections Table 3 Alarm Notification NOTE The following section is for information only and the features described are not neces...

Page 7: ... requests training or more information use the contact information given below Product Support Information Pre Sales Inquiries and Applications Support Please contact your local distributor ADTRAN Appli cations Engineering or ADTRAN Sales Post Sale Support Please contact your local distributor first If your local distributor cannot help please contact ADTRAN Technical Support and have the unit ser...

Page 8: ...r B A training course provided by the customer or authorized representative using training materials and instructions provided by the manufacturer grantee of the equipment used to encode analog signals or C An independent training course e g trade school or technical institution recognized by the manufacturer grantee of the equipment used to encode analog signals or D In lieu of the preceding trai...

Page 9: ...t the Industry Canada technical specifications were met Notice The Ringer Equivalence Number REN for this terminal equipment is supplied in the documentation or on the product labeling markings The REN assigned to each terminal device indicates the maximum number of terminals that can be connected to a telephone interface The termination on an interface may consist of any combination of devices su...

Page 10: ...200373L1 BCU with Fractional T1 1200373L2 PSU 1175006L2 Quad FXS 1175408L2 User Manual 61175408L1 1A Quad FXO 1175407L2 User Manual 61175407L1 1A AC Power Supply Battery Charger 1175043L2 Backup Battery Pack 1175044L1 L2 L4 Single Unit 19 Rack Mount Brackets 1175045L1 Single Unit 23 Rack Mount Brackets 1175046L1 Sample System Configuration Part Numbers Total Access 850 DC RCU Chassis Bundle 420037...

Reviews: