Appendix A. Understanding SNMP
SNMP MIB Browser Configuration
The steps required to configure Network Manager MIB
variable access through the TSU 610 are as follows:
1. Load the desired product MIBs on the network
management station. If, for example, the administrator is
managing TSU 610 and ISU 512 devices, load TSU
610e.MIB, ISU512.MIB, and RFC1406.MIB.
2. Create device entries in the NMS database for all units
that are to be managed through the TSU 610. The host
unit should be configured as the Proxy agent for the
external units. The IP address or host name used for the
proxy designation is that of the TSU 610.
3. Set community names in the device’s entries for external
units to the TSU 610 community name with the device
Unit ID appended as defined in the previous section,
TSU 610 SNMP ACCESS on page A-3.
4. Set the device timeout for all device entries in the NMS
device database to five seconds, including the host unit.