61202076L1-1
TSU 600 User Manual
B-1
Appendix B
Understanding TR-08
The TSU 600 chassis functions as a Remote Terminal in Digital Loop
Carrier
and as Integrated Digital Loop Carrier Systems as described in
TR-TSY 000008. The TSU 600 supports SLC96 framing, Mode I opera-
tion, ORB-13 and ORB-16 alarm formats, alarm reporting, and user-de-
finable BPV threshold detection rate.
A basic familiarity with DLC systems, IDLC systems, and TR-TSY-
000008 is assumed, but the following information will be useful:
•
All received TR-TSY-000008 specific alarms are reported locally
within the history feature of the TSU 600.
•
When the DISABLE ALARMS option is selected, no alarms will be
sent on the DLF, but received alarms will be reported locally in the
history.
•
Other alarms normally reported by the TSU 600 will also be placed
in history.
•
Each TSU 600 needs to be configured as the A SHELF, as it is provi-
sioned as a separate entity.
•
All alarms will refer to A SHELF when received from TSU 600.
Summary of Contents for 1202076L1
Page 18: ...List of Figures vi TSU 600 User Manual 61202076L1 1...
Page 20: ...List of Tables viii TSU 600 User Manual 61202076L1 1...
Page 54: ...Chapter 3 Operation 3 14 TSU 600 User Manual 61202076L1 1...
Page 76: ...Chapter 5 Configuration Menu 5 16 TSU 600 User Manual 61202076L1 1...
Page 98: ...Chapter 8 Telnet Terminal Menus 8 10 TSU 600 User Manual 61202076L1 1...
Page 106: ...Appendix B Understanding TR 08 B 4 TSU 600 User Manual 61202076L1 1...
Page 116: ...Appendix E Specifications E 4 TSU 600 User Manual 61202076L1 1...