1
Remove power from the unit.
2
Use a screwdriver to remove the cover plate from the option slot in the NetVanta base unit.
3
Slide the option module into the option slot until the module is firmly seated against the chassis
).
4
Secure the screws at both edges of the module using a screwdriver.
5
Connect the cables to the associated device(s).
6
Restore power to the unit.
T4
48VDC
GIG 0/1
STAT
FAN
GIG 0/2
GIG 0/3
GIG 0/4
GIG 0/5
CONSOLE
NetVanta 4660
1 PPS
OUT
1
2
3
4
Unit Installation
NetVanta 4660/5660 Series
30
Copyright © 2019 ADTRAN, Inc.
617004660F1-34B
Figure 9. Network Module Installation
Your NetVanta unit is now ready to be configured and connected to the network. For information on
configuration for a specific application, refer to the configuration guides provided online on
For details on the CLI, refer to the
AOS Command Reference Guide
. All other related
documents are also available online on
•
Electronic modules can be damaged by static electrical discharge. Before
handling modules, put on an antistatic discharge wrist strap to prevent damage
to electrical components. Place modules in antistatic packing material when
transporting or storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.
•
Always remove power from the unit prior to removing or installing a module.
•
Improper installation could result in damage to the modules.
Instructions for Installing the Network Modules
Step
Action