Specifications
provides BBU specifications.
Table 3. BBU Specifications
Your Total Access 900 Series unit is now ready to be configured and connected to the network. For
information on configuration for a specific application, refer to the configuration guides provided online
For details on the CLI, refer to the
All other related documents are also available online on
Battery
Part Number:
Suppliers:
Batteries:
Voltage:
Backup Time:
Wire Gauge:
311212V02
YUASA and Panasonic
7 Ahr per battery
-12 VDC per battery
Up to 8 hours
18 AWG
Environmental
Operating Temperatures:
Preferred:
Charge: 5°F to 122°F (-15°C to 50°C)
Discharge: -4°F to 140°F (-20°C to 60°C)