background image

Product Specifications

Electrical

■ Power is provided by a 12V DC Power Adapter that is included with the 825-v6. The power adapter operates from a power source of 100 to 240V AC, 

50 - 60 Hz. The nominal output is 12V DC +\–5% with a maximum current rating of 4.0 Amps. For US and Canadian applications, a UL Listed limited 

power source (LPS) is required. For deployment outside of North America, an LPS specifically approved for that country, such as a CE Mark, is 
required.

Environment

■ Operating Temperature: 32°F to 104°F (0°C to 40°C)
■ Storage Temperature: -40°F to 158°F (-40°C to 70°C)
■ Relative Humidity: 10 to 95 percent, non-condensing

Safety and Regulatory

This product meets the following compliance requirements:

■ UL /cUL Listed
■ FCC Part 15, Class B
■ ICES-003 (Class B)
■ IEC 62368-1
■ EN 62368-1, AS/NZS 60950.1
■ RoHS Compliant

This equipment contains no parts that can be serviced by the user.

Refer to the Safety and Regulator Notice for this product (P/N: 617600139F1-17) for detailed safety and regulatory information. 
Consultez l'avis sur la sécurité et la conformité à la réglementation pour ce produit (P/N: 617600139F1-17) pour obtenir des renseignements détaillés sur 

la sécurité et la réglementation.
Ausführliche Sicherheits- und regulatorische Informationen sind in der Konformitätserklärung zur Sicherheit und Einhaltung von Normen zu diesem 

Produkt (P/N: 617600139F1-17) aufgeführt. 

NOTE

g

It is strongly suggested that the power supply (a 5-foot (1.5 m) power cord) included with the 825-v6 be connected to a surge suppressor device 

which can have its own extension cable. The surge protection device should provide L-N, L-G, and N-G protection. It is also recommended that 

the device contains a visual 'GOOD' indicator.

NOTE

g

Changes or modifications not expressly approved by ADTRAN will void the warranty.

Documentation for ADTRAN Network Solutions products is 

available for viewing and download directly from the ADTRAN 

Support Community website. 

Go to: 

https://supportcommunity.adtran.com

ADTRAN offers training courses on our products, including 

customized training and courses taught at our facilities or at 

customer sites.

For inquiries, go to:

 

http://adtran.com/training

Access additional safety information and product documentation using the QR 

code or website.

https://supportcommunity.adtran.com

Warranty:

ADTRAN will replace or repair this product within the warranty period if it does not 

meet its published specifications or fails while in service. Warranty information can be 

found online at 

www.adtran.com/warranty

.

Trademarks:

 Brand names and product names included in this document are trademarks, 

registered trademarks, or trade names of their respective holders.

Copyright © 2021 ADTRAN, Inc. All Rights Reserved.

ADTRAN CUSTOMER CARE:

From within the U.S.     1.888.423.8726

From outside the U.S. +1 256.963.8716

PRICING AND AVAILABILITY  1.800.827.0807

617600139F1-13A

Summary of Contents for 617600139-13A

Page 1: ...ng cautions notes and installation instructions before installing or servicing this equipment f ATTENTION Lisez tous les avertissements et mises en garde avant l installation de cet équipement ou la réalisation de toute opération de maintenance f WARNING f CAUTION g NOTE WARNING indicates a hazard which if not avoided could result in death injury or serious property damage CAUTION indicates a haza...

Page 2: ...tions to install the 825 v6 desktop and wall mount Be sure to route and secure the fiber and cables in a manner that will prevent damage These options are described below Desktop Installation The 825 v6 can be placed on a desk or table The following table shows the recommended minimum distance in feet and meters between the gateway and household appliances to reduce interference NOTE g Refer to th...

Page 3: ... port 3x3 802 11ax 2 4GHz 4x4 802 11ax 5GHz 2x Telephone RJ 11 Connectors Tel 1 and Tel 2 ports 1x USB 3 0 Type A Connector port To connect the subscriber interfaces refer to Figure 2 and complete the following 1 For an Ethernet connection insert a Category 5E or better RJ 45 cable into one of the LAN ports labeled LAN 1 4 or the 2 5 Gigabit Ether net port 2 5GbE until there is an audible click Co...

Page 4: ...way enable you to monitor the device status This section describes the three types of LEDs available on the 825 v6 gateway See Figure 3 for details Figure 3 Status LEDs 2 4 GHz 5 GHz Status LEDs The 2 4 GHz and 5 GHz status LEDs indicate the state of the wireless connections on the gateway WPS Status LED The WPS status LED indicates the status of WPS Wi Fi protected setup Tel 1 2 Status LED The Te...

Page 5: ...iesem Produkt P N 617600139F1 17 aufgeführt NOTE g It is strongly suggested that the power supply a 5 foot 1 5 m power cord included with the 825 v6 be connected to a surge suppressor device which can have its own extension cable The surge protection device should provide L N L G and N G protection It is also recommended that the device contains a visual GOOD indicator NOTE g Changes or modificati...

Reviews: