background image

job

Aid

1

6540 Rear Panel

SHDSL

G.703

 Nx64K

V.35/V.36

X.21

100-240VAC 50/60Hz 100mA

CONTROL V.28

Express 6500 Series

6540 Front Panel

D

ESCRIPTION

The AC Powered 6540 SHDSL 2-Wire/4-Wire NTU (P/N 
1230001E1) functions as an interface between the SHDSL network 
and the Data Terminal Equipment (DTE).
The 6540 supports applications such as LAN-to-LAN bridging, 
Frame Relay circuit, and PABX termination.
The 6540 is designed to be used either as a remote unit to the 
ADTRAN Total Access

®

 

3000 multiservice platform, or as a pair of 

units in a point-to-point limited distance campus configuration, 
with one 6540 configured to “LT” mode.

F

EATURES

The 6540 supports the following features:

Housed in a standalone plastic case

Provides four front panel recessed pushbuttons, and eight 
front panel LED indicators

Provides rear panel SHDSL, G.703, and/or Nx64K ports, and 
a local management port

Provides a rear panel connection for local AC power

Provides bad splice protection using the ADTRAN 
proprietary Runtime TScan

 2.0 splice protection feature (for 

more information on this feature and how to locally manage 
TScan, refer to the 

SHDSL NTU, 2-Wire/4-Wire Product Series 

Installation and Maintenance Guide

, P/N 61230001E1-5).

LED I

NDICATORS

Label

Status

Description

SHDSL

{

z

z

z

Off
Green
Yellow
Red

Unit is powered off
Port is trained; no active alarms
Port is trained with a minor active alarm 

(1)

Port is attempting to or is trained with a major 
alarm

 (2)

SHDSL

6540 NTU 2-Wire/4-Wire

AC Powered

1. Minor SHDSL port alarms: CRC errors, Loop Attenuation Threshold Alarm, SNR 

Margin Threshold Alarm, Segment Anomaly, and any ES, SES, UAS, CVC, and 

LOSWS 15-Minute Threshold Alarm

2. Major SHDSL port alarms: LOS, LOSW, or Segment Defect

3. Minor G.703 port alarms: Rx RAI, Frame Slip, CRC-4 errors, LBER, and any ES, 

SES, UAS, and CVC 15-Minute Threshold Alarm

4. Major G.703 port alarms: LOS, LOF, LOMF, Rx AIS, or HBER

5. Nx64K port alarms: Clock Slip, Loss of External Clock, FIFO Underflow/Over-

flow, and Inactivity Alarm

G.703

{

z

z

z

Off
Green
Yellow
Red

Port is not active
Active Port with no active alarm
Active Port with a minor alarm 

(3)

Active Port with a major alarm 

(4)

NX64K

{

z

z

Off
Green
Red

Port is not active
Active Port with no active alarm
Active Port with an active alarm condition 

(5)

RTS/C

{

z

Off

Green

Nx64K port is not active or when active, V.35/

V.36 “Request To Send” or X.21 “Control” line 

from the DTE is off
V.35/V.36 “Request To Send” or X.21 “Con-

trol” line from the DTE is on

RLSD/I

{

z

Off

Green

Nx64K port is inactive or when active, V.35/

V.36 “Receive Line Signal Detector” and X.21 

“Indication” control line from the NTU is off.
V.35/V.36 “Receive Line Signal Detector” or 

X.21 “Indication” control line from the NTU 

(DCE) is on

LLOOP

{

z

z

Off
Yellow
Red

Local Loop is not active
Active Local Loopback on the selected port
Active Local Loop on one or more ports or ser-

vices (when no port is selected) 

RLOOP

{

z

z

Off
Yellow

Red

Remote Loop is not active
Active Remote Loopback on the selected port 

(when determined via established EOC)
Active Remote Loop on one or more ports or 

services (when no port is selected)

BERT

{

z

z

z

Off
Green

Yellow

Red

BERT is not active
Active BERT and the test pattern detector is 

synchronized with no received bit errors
Active BERT and one or more test pattern bit 

errors have been received
Active BERT but the test pattern detector is 

not synchronized

Label

Status

Description

Product P/N: 1230001E1

Issue Date: September 2011

Document P/N: 61230001E1-22C

Summary of Contents for 6540

Page 1: ...WS 15 Minute Threshold Alarm 2 Major SHDSL port alarms LOS LOSW or Segment Defect 3 Minor G 703 port alarms Rx RAI Frame Slip CRC 4 errors LBER and any ES SES UAS and CVC 15 Minute Threshold Alarm 4 Major G 703 port alarms LOS LOF LOMF Rx AIS or HBER 5 Nx64K port alarms Clock Slip Loss of External Clock FIFO Underflow Over flow and Inactivity Alarm G 703 z z z Off Green Yellow Red Port is not acti...

Page 2: ...té et la réglementation Ausführliche Sicherheits und regulatorische Informationen sind in der Konformitätserklärung zur Sicherheit und Einhaltung von Normen zu diesem Produkt 6123001E1 17 aufgeführt PUSH BUTTONS MAINTENANCE The 6540 does not require routine hardware maintenance for normal operation Do not attempt repairs in the field Repair services may be obtained by returning the defective unit ...

Page 3: ...t 3 Customer Non Transparent 4 Network Transparent 5 Network Non Transparent 1 ALT 2 2047 3 2E15 1 4 QRSS 5 Test Options 1 Permanent Off 2 DTE Driven 1 LTU 2 NTU 1 Interface Mode 2 Payload Rate kbps 3 SNR Margin Alarm Threshold dB 4 Loop Attenuation Alarm Threshold dB 5 Outage Auto Retrain 6 PM Thresholds 1 Disabled 2 Enabled 0 Disabled 1 900 Seconds 1 Disabled 2 Enabled 1 Disabled 2 Enabled 00h t...

Page 4: ...adtran com Warranty ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service Warranty information can be found online at www adtran com warranty 2011 ADTRAN Inc All Rights Reserved ADTRAN CUSTOMER CARE From within the U S 1 800 726 8663 From outside the U S 1 256 963 8716 PRICING AND AVAILABILITY 1 800 827 0807...

Reviews: