background image

Logging Into the 831-t5

831-t5 Mesh AP QSG

4

6SDG831T5-13A

Logging Into the 831-t5

A browser-based graphical user interface (GUI) is used to manually configure the 831-t5. The following steps describe how to connect and login 

to the device:

1. Ensure your computer is connected to the 831-t5 either via Wi-Fi or Ethernet connection to the LAN port.
2. Configure your computer’s network interface to acquire an IP address automatically using DHCP.
3. Open a web browser and enter the following: 

http://router

 or 

http://setup

. A sign-in page should appear. If you are unable to connect to 

the 831-t5 using either of these shortcuts, you can also enter the IP address of the unit. The default IP address is 

192.168.0.1

.

4. Enter the default username and password. The default username is 

admin

 and the default password is 

admin

.

5. Select 

Sign In

. The 

Dashboard

 page appears, showing data about the system.

Product Specifications

Electrical

■ Power is provided by a 12V DC power adapter that is included with the 831-t5. The power adapter operates from a power source of 100 to 

240V AC, 50 - 60 Hz. The nominal output is 12V DC ±5% with a minimum current rating of 3.0 Amps. For US and Canadian applications, a 

UL Listed limited power source (LPS) is supplied and required for use. For deployment outside of North America, an LPS specifically 

approved for that country, such as a CE Mark, is supplied and required for use.

Environment

■ Operating Temperature: 32°F to 104°F (0°C to 40°C)
■ Storage Temperature: -40°F to 158°F (-40°C to 70°C)
■ Relative Humidity: 10 to 95 percent, non-condensing

Compliance

This product meets the following compliance requirements:

■ UL /cUL Listed
■ FCC Part 15, Class B
■ ICES-003 (Class B)
■ IEC 62368-1
■ EN 62368-1, AS/NZS 62368.1
■ RoHS Compliant

NOTE

g

If you have forgotten the password for this device, select 

Forgot password?

 and follow the instructions to reset the device to the factory 

defaults. Next, follow the instructions under 

“Quick Setup for the 831-t5” 

on page 3

.

NOTE

g

It is strongly suggested that the power supply (a 5-foot (1.5 m) power cord) included with the 831-t5 be connected to a surge suppressor 

device which can have its own extension cable. The surge protection device should provide L-N, L-G, and N-G protection. It is also 

recommended that the device contains a visual 'GOOD' indicator.

NOTE

g

Changes or modifications not expressly approved by Adtran will void the warranty.

Summary of Contents for 831-t5

Page 1: ...page 5 Figure 1 831 t5 Mesh AP WARNING f Read all warnings cautions notes and installation instructions before installing or servicing this equipment 12VDC Power Input Reset Button 1G LAN USB 3 0 Host...

Page 2: ...he national state and local electrical codes for the requirements for power grounding wiring and installation methods CAUTION f The product is intended for indoor use only Ethernet and attached equipm...

Page 3: ...re is designed to simplify the pairing process between the devices Perform the following steps to activate WPS 1 Press the WPS button on the back of the 831 t5 for less than 5 seconds for 5GHz or more...

Page 4: ...l output is 12V DC 5 with a minimum current rating of 3 0 Amps For US and Canadian applications a UL Listed limited power source LPS is supplied and required for use For deployment outside of North Am...

Page 5: ...radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance of 25 cm between the radiator and your body This device and i...

Page 6: ...B NMB 3 B Canadian Department of Communications Radio Interference Regulations This digital apparatus Wi Fi 5 Mesh Access Point Model 831 t5 does not exceed the Class B limits for radio noise emissio...

Page 7: ...n maximal d antenne permis pour les dispositifs utilisant la bande de 5725 5850MHz doit tre conforme la limite de la p i r e sp cifi e pour l exploitation point point et l exploitation non point point...

Reviews: