background image

C A U T I O N 

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

Warranty

: ADTRAN will replace or repair this product 

within the warranty period if it does not meet 

its published specifications or fails while in 

service. Warranty information can be found 

online at

 www.adtran.com/warranty

.

©2014 ADTRAN, Inc. All Rights Reserved.

*61442941F1-22B*

ADTRAN CUSTOMER CARE:

From within the U.S.     1.800.726.8663

From outside the U.S. +1 256.963.8716

PRICING AND AVAILABILITY  1.800.827.0807

S

PECIFICATIONS

Optical Specifications:

o

Transmit Wavelength: 1530 to 1565 nm

o

Receive Wavelength: 1270 to 1600 nm

o

Data rate: 9.95 Gb/s to 11.35 Gb/s

o

Optical transmit level: –1.0 to +2.0 dBm

o

Optical receive level: –15.0 to –1.0 dBm

o

Optical distance: 40 km maximum

o

Optical connectors: LC

Extended Environmental Support:

o

Operational temperature range: –40°C to +65°C

o

Storage temperature range: –40°C to +85°C

o

Relative humidity to 85%, noncondensing

S

AFETY

 

AND

 R

EGULATORY

 C

OMPLIANCE

WARNING

!

Read all warnings and cautions before installing or servicing this
equipment.

CAUTION

C

The XFP is a Class 1 Laser Product and complies with the Laser
Safety requirements of FDA 21CFR 1040.10 and 1040.11, and
EN60825-1 and -2. The XFP is NRTL listed and CB Certified to all
applicable American and European safety standards.
For continued compliance with the above laser safety standards,
only approved Class 1 modules from our approved vendor list,
located on the ADTRAN website, should be installed in ADTRAN
products.

CAUTION

!

Electrostatic Discharge (ESD) can damage electronic modules.
When handling modules, wear an antistatic discharge wrist
strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or
storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.

The XFP meets or exceeds all the applicable requirements of
NEBS, Telcordia GR-63-CORE, and GR-1089-CORE. The XFP
is intended for deployment in Central Office type facilities,
EEEs, EECs, and locations where the NEC applies (for
example, Customer Premises). The XFP is to be installed in
ADTRAN products in Restricted Access Locations only, and
installed by trained service personnel.

Per GR-1089-CORE, the ADTRAN system in which the XFP is
being deployed is designed and intended for installation as
part of a Common Bonding Network (CBN). The ADTRAN
system in which the SFP is being deployed is not designed nor
intended for installation as part of an Isolated Bonding
Network (IBN).

Per GR-1089-CORE Section 9, the XFP does not have an
internal DC connection between battery return and frame
ground. The XFP can be installed in a DC-I (isolated) or DC-C
(common) installation. For installations where other cards or
the host system have internal connections between battery
return and frame ground, the system would be intended for
deployment only in a DC-C installation.

The ADTRAN system chassis frame ground terminal must be
connected to a reliable earth ground to ensure that the metal
enclosure of the XFP is properly grounded via the backplane
connector.

NOTE

The Gigabit Ethernet port(s) are optical and therefore are not
classified as any type of port as defined in Appendix B of GR-
1089-CORE.

This product is designed to be deployed in GR-3108-CORE
environmental Class 1, 2, & 3.

This device complies with FCC 47 CFR Part 15, Class B. Operation 
is subject to the following two conditions:

1. This device may not cause harmful interference.
2. This device must accept any interference received, including 

interference that may cause undesired operation.

Changes or modifications not expressly approved by ADTRAN 
could void the user's authority to operate this equipment.
The XFP is designed to meet the following environmental classes:

ETSI EN 300 019-1-1 “Classification of environmental 
conditions; Storage,” Class 1.2

ETSI EN 300 019-1-2 “Classification of environmental 
conditions, Transportation,” Class 2.3

ETSI EN 300 019-1-3 “Classification of environmental 
conditions, Stationary use at weather-protected locations,” 
Class 3.3

The equipment is designed to function without degradation 
during exposure to all test severities per Class 3.3.
This product meets EU RoHS Directive 2002/95/EC and/or 
applicable exemptions. Refer to 

www.adtran.com

 for further 

information on RoHS/WEEE.

Reviews: