NetVanta 6310/6330 Series Hardware Installation Guide
Unit Installation
61700100G1-34F
Copyright © 2013 ADTRAN, Inc.
39
Figure 18. Wallmount Installation
•
To avoid damaging the unit, use only the screws included in the shipment when
attaching mounting ears to the chassis.
•
When wall mounting the NetVanta, care must be taken not to damage the power cord.
Do not attach the power cord to the building surface or run it through walls, ceilings.
floors, or openings in the building structure.
•
The socket-outlet must be installed near the equipment and must be easily accessible.
Instructions for Wall Mounting the NetVanta
Step
Action
1
Remove the mounting ears. Rotate them 90 degrees so that the portion of the bracket with the
mounting holes is flush with the bottom of the chassis. Reattach the mounting ears to the
chassis (see
Figure 18
).
2
Decide on a location for the NetVanta, keeping in mind that the unit needs to be mounted at or
below eye-level so that the LEDs are viewable. The NetVanta 6310 can only be wall mounted
with the front panel facing to the right (see
Figure 18
).
3
Prepare the mounting surface by attaching a board (typically plywood, 3/4-inch to 1-inch thick)
to a wall stud using #6 to #10 (2.5-inch or greater in length) wood screws.
Important! Mounting to a stud ensures stability. Using sheetrock anchors may not provide
sufficient long-term stability.
4
Have an assistant hold the unit in position as you install two #6 to #10 (1-inch or greater in
length) wood screws through the unit’s brackets and into the mounted board (see
Figure 18
).
5
Proceed to the steps given in
Supplying Power to the Unit on page 40
.