Quick Start Guide, 61700120G1-13B, August 2015
1
N
ET
V
ANTA
6330 S
ERIES
P/N 47006332G1, 47006334G1, 47006336G1, 47006337G1, 47026332F1,
47026334F1, 47026336F1, 47026337F1
4
Copyright © 2015 ADTRAN, Inc. All Rights Reserved.
G
ETTING
S
TARTED
Two configuration methods are available for your NetVanta 6330 Series units:
•
Web-based graphical user interface (GUI)
•
AOS command line interface (CLI)
The GUI lets you configure the main unit settings and provides online guidance and explanations for each
setting. However, using the AOS CLI may be necessary for more advanced configurations.
A
CCESS
THE
GUI
You can access the GUI from any web browser on your network by following these steps:
1.
Connect the unit to your PC, using an Ethernet cable connected to the
ETH 0/1
port on the back of the
unit.
2.
Set your PC to a fixed IP address in the 10.10.10.0 /24 subnet. For example configure your PC with the
following settings:
IP Address:
10.10.10.2
Subnet Mask:
255.255.255.0
Neither a default gateway nor DNS server needs to be configured to connect to the unit. If you cannot
change your PC’s IP address, you will need to change the Unit’s IP address using the CLI as explained in
the section below.
3.
Open a web browser and enter the unit’s IP address in your browser address line as follows:
http://10.10.10.1
. The default IP address is
10.10.10.1
, but if you had to change the unit’s IP address
using the CLI, enter that address in the browser line.
4.
You will then be prompted for the user name and password (the default settings are
admin
and
password
).
5.
The initial GUI screen appears.
6.
ADTRAN recommends changing the default password. Browse to
System > Passwords.
In the Login
Configuration section, enter a new
Username
and
Password
and select
Apply Change
s.
A
CCESS
THE
CLI
Access the AOS CLI via the
CONSOLE
port, Telnet, or SSH session. To establish a connection to the NetVanta
unit
CONSOLE
port, you need the following items:
•
PC with VT100 terminal emulation software
•
Straight-through serial cable with a DB-9 (male) connector on one end and the appropriate interface for
your terminal or PC communication port on the other end.
There are many terminal emulation applications available on the web. PuTTY,
SecureCRT, and HyperTerminal are a few examples.
N
ET
V
ANTA
6330 D
EFAULTS
R
ESTORING
F
ACTORY
D
EFAULTS
For information on restoring factory defaults, refer to the guide
Restoring an AOS Device to Factory Default
https://supportforums.adtran.com
Feature
Default Value
IP Address
10.10.10.1
User Name
admin
Password
password
HTTP Server
Enabled
Event History
On
IP Routing
Enabled