SmartRG Inc., an ADTRAN Company Proprietary and Confidential. All Right Reserved. © 2020
127
b. Modify the fields, using the information provided in the
Ethernet Service OAM (802.1ag/Y.1731)
section of the table below.
4. Click
Apply/Save
to commit your changes.
5. To run a loopback test, enter a MAC address in the
Target MAC
field and click
Send Loopback
at the bottom of the
page. The results appear in the
Loopback Result
row of the table.
6. To run a linktrace test, enter a MAC address in the
Target MAC
field and click
Send Linktrace
at the bottom of the
page. The results appear in the
Linktrace Result
t row of the table.
The fields on this page are defined below.
Field Name
Description
Ethernet Link OAM (802.3ah)
section
WAN Interface
Select the WAN interface that you want to test.
OAM ID
Enter the ID of this OAM configuration. Only positive numbers are allowed.
Auto Event
Click to enable automatic reporting of events.
Variable Retrieval
Click to enable on-demand link diagnostics, including bit-error-rate approximation.
Link Events
Click to enable reporting of critical conditions that may cause link failure.