Total Access
®
3000/3010 System Manual
6TAAPP336-1E
TOTAL ACCESS 3000/3010
APP-336
Page 2 of 6
© 2002, ADTRAN, Inc.
1.1.3
Total Access Deployment Guidelines for HDSL2
The ADTRAN Total Access 3000/3010 system is designed to deliver HDSL2-based
services over loops that are in compliance with the Carrier Service Area (CSA)
guidelines listed below:
• All loops must be non-loaded.
• The maximum loop length, including bridge tap, for 26 AWG cable is 9 kft.
• The maximum loop length, including bridge tap, for 24 AWG cable is 12 kft.
• Any single bridged tap is limited to 2 kft.
• Total bridged tap is limited to 2.5 kft.
• The total length of multi-gauge cable containing 26 AWG cable must not exceed
the following:
12 – {(3*L
26
) / (9 – L
BTAP
(in kft.)}
L
26
= Total length of 26 AWG cable excluding bridge taps (in kft.)
L
BTAP
= Total length of all bridge taps (in kft.).
1.1.2
HDSL2 Circuit With One H2R
Figure 2
illustrates a typical HDSL2 circuit with the use of one H2R.
Central Office
Remote Site
H2TU-R
H2TU-C
H2R
Total Access 3000/3010 Chassis
12 Kft
(2-wire)
12 Kft
(2-wire)
DS1
Figure 2. HDSL2 Circuit With One H2R