6TANTP501-1E
TOTAL ACCESS 3000/3010
NTP-501
Page 20 of 22
© 2002, ADTRAN, Inc.
Total Access
®
3000/3010 System Manual
16.From the General Menu, select option 4,
Auto-Logoff
, and press <Enter>.
17.To enable the Auto-Logoff, select option 2,
Enable
, and press <Enter>.
18.The current menu will now be the General Menu.
19.From the General Menu, select option 6,
READ_ONLY Password
, and press
<Enter>.
20.Enter the alphanumeric READ_ONLY password and press <Enter>.
21.The current menu will now be the General Menu.
22.From the General Menu, select option 7,
READ_WRITE Password
, and press
<Enter>.
23.Enter the alphanumeric READ_WRITE password and press <Enter>.
24.The current menu will now be the General Menu.
25.To return to the Provisioning Menu, press <Esc>.
26.From the Provisioning Menu, select option 2,
MUX/Module
, and press <Enter>.
27.From the MUX/Module Menu, select option3,
MUX Auto-Provisioning
, and press
<Enter>.
28.To Enable or Disable MUX Auto-Provisioning, select the corresponding number
and press <Enter>.
29.The current menu will now be the MUX/Module Menu.
30.From the MUX/Module Menu, select option 4, Module Auto-Provisioning, and
press <Enter>.
31.To Enable or Disable Module Auto-Provisioning, select the corresponding number
and press <Enter>.
32.The current menu will now be the MUX/Module Menu.
33.To return to the main menu press <Enter>.
1.14.9
Repeat 1.14.1 Through 1.14.8 for Each Shelf
Each individual shelf must be tested and provisioned as described above. For each
shelf to be installed, repeat Steps 1.14.1 through 1.14.8.
NOTE
The Host SCU in any chain connected by the RS-485 bus must be the end
SCU on the chain. It does not matter which end has the Host SCU, but the
single Host cannot be in the middle of the daisy chain. Typically, the Host
SCU should be the first in the chain.