6TANTP506-1E
TOTAL ACCESS 3000/3010
NTP-506
Page 4 of 4
© 2002, ADTRAN, Inc.
Total Access
®
3000/3010 System Manual
2. Allow the unit approximately 60 seconds to completely power up and synchronize
with the SCU. Upon completion, the POWER LED will be flashing yellow,
indicating an Out-of-Service, Unassigned (OOS-UA) state and the Online LED
will be off. The STATUS and OPTICS LEDs will be red and the CLOCK LED
will be yellow.
3. Proceed to DLP-742 for procedure to provision the OC-3 MUX modules.
1.5
Placing the Units in Service
NOTE
Ensure all alarms are cleared before placing the modules In-Service. This will
prevent false alarms from being transmitted to the network.
1. From the working MUX Menu, select option 2,
Provisioning
, and press <Enter>.
2. From the Provisioning Menu, select option 1,
Service State
, and press <Enter>.
3. From the Service State Menu, select option 1,
In Service
, and press <Enter>.
4. Repeat the above steps for the Protect MUX.
NOTE
At this point the Power LED on both MUX modules will illuminate green,
indicating an In-Service state. Alarms will also be generated in this state.
MUX A Online LED should be illuminated green and MUX B Online LED
should be off. The Status LED on both MUX units should be green if an OC-3
signal is present and synchronized. If no OC-3 signal is present, both LEDs
will be illuminated red.