6TANTP513-1E
TOTAL ACCESS
3000/3010
NTP-513
Page 6 of 8
© 2002, ADTRAN, Inc.
Total Access
®
3000/3010 Systems Manual
Perform Steps Below in the Order Listed
1.5
Reset All Equipment To Operating Condition
When the customers at both ends of the circuit have turned up their equipment and are
running data (or test patterns, or are in loopbacks, or some other condition that will
preclude the generation of alarms), the HTU-Cs can be placed
In Service
to restore the
alarm generating functions of the equipment to the network.
1. From the Total Access 3000 HTU-C Provisioning Screen for both the MAIN and
AUX HTU-Cs, select the
Service State
option, and place both HTU-Cs
In Service
.
NOTE
Placing the HTU-Cs
In Service
will change the PWR LED from slow flashing
green to steady green.
1.6.
Disabling Protection Switching
Disabling the protection switching mode from the circuit converts both the MAIN and
AUX circuits into independent stand-alone HDSL circuits.
CAUTION
Ensure that data has been removed from the aux circuit before proceeding
with the next step. Disabling protection switching before removing data
from the AUX loop will cause a loss of signal condition on that loop.
Under
normal circumstances, the data on the HLSS circuit will be running on the
MAIN HDSL circuit, and this precaution is unnecessary.
1.6.1
Disabling protection switching
1. Access the AUX HTU-C and select Option 2,
Provisioning
, from the HDSL Main
Menu.
2. From the Provisioning menu, choose the
Service State
option.
3. Select Option 3, Out Of Service-Unassigned.
4. Escape out of the AUX HTU-C menus and proceed to the MAIN HTU-C menu.
5. From the Main Menu, select Option 7, Protection Configuration.
6. From the Protection Configuration menu, select Option 1, Protection Mode.
7. Choose Option 2, Disable.